Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study evaluates the predictive power of the critical flicker fusion frequency (CFF) test for visual outcomes in keratoprosthesis (KPro) candidates, comparing its accuracy with B-scan ultrasound, flash visual evoked potentials (fVEP) and endoscopy.

Methods: The study included 42 patients (42 eyes) scheduled for KPro surgery with a median follow-up period of 6 months. The receiver operating characteristic curve identified the cut-off threshold for CFF in the model development study (17 eyes). All patients in the comparison study (25 eyes) underwent preoperative assessments including trichromatic CFF (red, green and yellow), B-scan ultrasound, fVEP and perioperative endoscopy. Results were classified as either favourable or unfavourable predictors of visual outcomes based on predefined criteria. Sensitivity and specificity of each assessment were calculated based on postoperative best-corrected visual acuity (BCVA)≥20/200. The Bland-Altman test assessed the consistency between CFF-predicted BCVA and actual BCVA.

Results: Among the trichromatic CFF tests, the yellow-CFF (yCFF) exhibited the highest area under the curve value of 0.97 and a cut-off threshold at 10 Hz for predicting postoperative BCVA≥20/200 (p<0.05). yCFF achieved 90% sensitivity and 80% specificity in predicting satisfactory postoperative outcomes. Endoscopy had 80% sensitivity and 80% specificity, B-scan showed 70% sensitivity and 60% specificity, and fVEP had 75% sensitivity and 40% specificity. yCFF showed a mean bias of 0.091 logarithm of the minimum angle of resolution (logMAR) in postoperative prediction.

Conclusions: The CFF test provides robust visual function evaluation in KPro candidates. It demonstrates superior predictive accuracy for visual prognosis compared with routine ophthalmologic examinations, such as B-scan ultrasonography, fVEP and endoscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjo-2024-325719DOI Listing

Publication Analysis

Top Keywords

visual outcomes
12
outcomes keratoprosthesis
8
critical flicker
8
flicker fusion
8
fusion frequency
8
b-scan ultrasound
8
cut-off threshold
8
study eyes
8
trichromatic cff
8
visual
5

Similar Publications

Background: Migraine care is often suboptimal owing to undertreatment, variation in clinical outcomes and administration methods among existing treatments, and between- and within-individual heterogeneity in the clinical course of migraine. In response to these challenges, preference studies have been increasingly conducted to inform treatment decision-making and development. However, gaps remain in understanding how treatment preferences have been assessed across different migraine studies.

View Article and Find Full Text PDF

Purpose: To investigate the images and treatment differences for Type IIIa atlantoaxial rotary dislocation (AARD) by comparing the imaging characteristics of patients with Type III and Type IIIa AARD.

Methods: The present study retrospectively analyzed a cohort of 35 patients who underwent posterior C1-C2 intra-articular fusion due to AARD from our hospital database. Among them, 23 patients were diagnosed with Type III AARD, while the remaining 12 patients were diagnosed with Type IIIa AARD.

View Article and Find Full Text PDF

The ability to detect small errors between sensory prediction in the brain and actual sensory feedback is important in rehabilitation after brain injury, where motor function needs to be restored. To date in the recent study, a delayed visual error detection task during upper limb movement was used to measure this ability for healthy participants or patients. However, this ability during walking, which is the most sought-after in brain-injured patients, was unclear.

View Article and Find Full Text PDF

Background: Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.

View Article and Find Full Text PDF

Objective: To evaluate clinical and laboratory effectiveness of ultrasound treatment for purulent wounds.

Material And Methods: The study enrolled 46 patients with purulent wounds divided into the main group (23 patients, ultrasonic treatment) and the control group (23 patients, traditional treatment). We assessed treatment effectiveness considering visual data, quality of granulation tissue, wound defect area and marginal epithelialization, complete blood count and C-reactive protein.

View Article and Find Full Text PDF