A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Seated Pulmonary Artery Pressure Monitoring in Patients With Heart Failure: Results of the PROACTIVE-HF Trial. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Monitoring supine pulmonary artery pressures to guide heart failure (HF) management has reduced HF hospitalizations in select patients.

Objectives: The purpose of this study was to evaluate the effect of managing seated mean pulmonary artery pressure (mPAP) with the Cordella Pulmonary Artery sensor on outcomes in patients with HF.

Methods: Following GUIDE-HF (Hemodynamic-GUIDEd Management of Heart Failure Trial), with U.S. Food and Drug Administration input, PROACTIVE-HF (A Prospective, Multi-Center, Open Label, Single Arm Clinical Trial Evaluating the Safety and Efficacy of the Cordella Pulmonary Artery Sensor System in NYHA Class III Heart Failure Patients trial) was changed from a randomized to a single-arm, open label trial, conducted at 75 centers in the USA and Europe. Eligible patients had chronic HF with NYHA functional class III symptoms, irrespective of the ejection fraction, and recent HF hospitalization and/or elevated natriuretic peptides. The primary effectiveness endpoint at 6 months required the HF hospitalization or all-cause mortality rate to be lower than a performance goal of 0.43 events/patient, established from previous hemodynamic monitoring trials. Primary safety endpoints at 6 months were freedom from device- or system-related complications or pressure sensor failure.

Results: Between February 7, 2020, and March 31, 2023, 456 patients were successfully implanted in modified intent-to-treat cohort. The 6-month event rate was 0.15 (95% CI: 0.12-0.20) which was significantly lower than performance goal (0.15 vs 0.43; P < 0.0001). Freedom from device- or system-related complications was 99.2% and freedom from sensor failure was 99.8% through 6 months.

Conclusions: Remote management of seated mPAP is safe and results in a low rate of HF hospitalizations and mortality. These results support the use of seated mPAP monitoring and extend the growing body of evidence that pulmonary artery pressure-guided management improves outcomes in heart failure. (Multi-Center, Open Label, Single Arm Clinical Trial Evaluating the Safety and Efficacy of the Cordella Pulmonary Artery Sensor System in NYHA Class III Heart Failure Patients trial [PROACTIVE-HF]; NCT04089059).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchf.2024.05.017DOI Listing

Publication Analysis

Top Keywords

pulmonary artery
28
heart failure
20
cordella pulmonary
12
artery sensor
12
open label
12
class iii
12
seated pulmonary
8
artery pressure
8
multi-center open
8
label single
8

Similar Publications