Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Surgical robotics application in the field of minimally invasive surgery has developed rapidly and has been attracting increasingly more research attention in recent years. A common consensus has been reached that surgical procedures are to become less traumatic and with the implementation of more intelligence and higher autonomy, which is a serious challenge faced by the environmental sensing capabilities of robotic systems. One of the main sources of environmental information for robots are images, which are the basis of robot vision. In this review article, we divide clinical image into direct and indirect based on the object of information acquisition, and into continuous, intermittent continuous, and discontinuous according to the target-tracking frequency. The characteristics and applications of the existing surgical robots in each category are introduced based on these two dimensions. Our purpose in conducting this review was to analyze, summarize, and discuss the current evidence on the general rules on the application of image technologies for medical purposes. Our analysis gives insight and provides guidance conducive to the development of more advanced surgical robotics systems in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11321255PMC
http://dx.doi.org/10.1093/nsr/nwae186DOI Listing

Publication Analysis

Top Keywords

surgical robotics
12
advances surgical
4
robotics image-guided
4
image-guided classification
4
classification application
4
surgical
4
application surgical
4
robotics application
4
application field
4
field minimally
4

Similar Publications

This Letter to the Editor responds to the recent publication by Patel et al. (J Robot Surg. Jul 11;19(1):370, 2025), which outlines a framework and recommendations for telesurgery.

View Article and Find Full Text PDF

Purpose: We aimed to evaluate the impact of day- and night-time pad wetness on 2yrs-QoL after Radical Cystectomy (RC) with Orthotopic Neobladder (ON) from a Randomized Controlled Trial (RCT) aimed at comparing open RC (ORC) and Robot-Assisted RC (RARC) with intracorporeal (i) ON.

Methods: Between January 2018 and September 2020, 116 patients were enrolled. Data from self-assessed questionnaires (EORTC-QLQ-C30 and QLQ-BLM30) were collected.

View Article and Find Full Text PDF

Renal transplantation is the best option for end-stage renal disease, and in this study, patients who underwent robotic-assisted renal transplantation (RAKT) and open renal transplantation (OKT) were selected to compare their intraoperative and postoperative clinical outcomes: including Operation Time, Length of Stay, WIT (warm ischaemia time), CIT (cold ischaemia time), Estimated Blood Loss, Post 1 month Creatinine, Incision Length, Rewarming Time, Wound infection. The study was registered in PROSPERO with CRD code: CRD420251061084. We searched in Web of Science, Pubmed, Wiely, Elsevier databases, screened according to inclusion and exclusion criteria and finally included 7 papers.

View Article and Find Full Text PDF