Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: The diagnosis of mild-moderate equine asthma (MEA) can be confirmed by airway endoscopy, bronchoalveolar lavage fluid (BALf) cytology, and lung function evaluation by indirect pleural pressure measurement. Oscillometry is a promising pulmonary function test method, but its ability to detect subclinical airway obstruction has been questioned.
Objectives: To evaluate the differences in lung function measured by oscillometry between healthy and MEA-affected horses.
Study Design: Prospective case-control clinical study.
Methods: Thirty-seven horses were divided into healthy and MEA groups, based on history and clinical score; the diagnosis of MEA was confirmed by airway endoscopy and BALf cytology. Horses underwent oscillometry at frequencies ranging from 2 to 6 Hz. Obtained parameters included whole-breath, inspiratory, expiratory, and the difference between inspiratory and expiratory resistance (Rrs) and reactance (Xrs). Differences between oscillometry parameters at different frequencies were evaluated within and between groups by repeated-measures two-way ANOVA and post hoc tests with Bonferroni correction. Frequency dependence was compared between groups by t test. For significant parameters, a receiver operating characteristics curve was designed, cut-off values were identified and their sensitivity and specificity were calculated. Statistical significance was set at p < 0.05.
Results: No significant differences in Xrs and Rrs were observed between groups. The frequency dependence of whole-breath and inspiratory Xrs significantly differed between healthy (respectively, -0.03 ± 0.02 and -0.05 ± 0.02 cmHO/L/s) and MEA (-0.1 ± 0.03 and -0.2 ± 0.02 cmHO/L/s) groups (p < 0.05 and p < 0.01). For inspiratory Xrs frequency dependence, a cut-off value of -0.06 cmHO/L/s was identified, with 86.4% (95% CI: 66.7%-95.3%) sensitivity and 66.7% (95% CI: 41.7%-84.8%) specificity.
Main Limitations: Sample size, no BALf cytology in some healthy horses.
Conclusions: Oscillometry can represent a useful non-invasive tool for the diagnosis of MEA. Specifically, the evaluation of the frequency dependence of Xrs may be of special interest.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11982413 | PMC |
http://dx.doi.org/10.1111/evj.14206 | DOI Listing |