A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessment of Effectiveness of the Algorithm for Automated Quantitative Analysis of Metallic Strut Tissue Short-Term Coverage with Intravascular Optical Coherence Tomography. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Due to its high resolution, optical coherence tomography (OCT) is the most suitable modality for neointimal coverage assessments. Evaluation of stent healing seems crucial to accurately define their safety profile since delayed healing is connected with stent thrombosis. This study aimed to present an algorithm for automated quantitative analysis of stent strut coverage at the early stages of vessel healing in intravascular OCT. A set of 592 OCT frames from 24 patients one month following drug-eluting stent implantation was used to assess the algorithm's effectiveness. Struts not covered on any side or covered but only on one side were categorized as uncovered. The algorithm consists of several key steps: preprocessing, vessel lumen segmentation, automatic strut detection, and measurement of neointimal thickness. The proposed algorithm proved its efficiency in lumen and stent area estimation versus manual reference. It showed a high positive predictive value (PPV) (89.7%) and true positive rate (TPR) (91.4%) in detecting struts. A qualitative assessment for covered and uncovered struts was characterized by high TPR (99.1% and 80%, respectively, for uncovered and covered struts) and PPV (77.3% and 87%). The proposed algorithm demonstrated good agreement with manual measurements. Automating the stent coverage assessment might facilitate imaging analysis, which might be beneficial in experimental and clinical settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11313088PMC
http://dx.doi.org/10.3390/jcm13154336DOI Listing

Publication Analysis

Top Keywords

algorithm automated
8
automated quantitative
8
quantitative analysis
8
optical coherence
8
coherence tomography
8
covered side
8
proposed algorithm
8
stent
6
algorithm
5
assessment effectiveness
4

Similar Publications