98%
921
2 minutes
20
Phase four of the Alzheimer's Disease Neuroimaging Initiative (ADNI4) magnetic resonance imaging (MRI) protocols aim to maintain longitudinal consistency across two decades of data acquisition, while adopting new technologies. Here we describe and justify the study's design and targeted biomarkers. The ADNI4 MRI protocol includes nine MRI sequences. Some sequences require the latest hardware and software system upgrades and are continuously rolled out as they become available at each site. The main sequence additions/changes in ADNI4 are: (1) compressed sensing (CS) T1-weighting, (2) pseudo-continuous arterial spin labeling (ASL) on all three vendors (GE, Siemens, Philips), (3) multiple-post-labeling-delay ASL, (4) 1 mm isotropic 3D fluid-attenuated inversion recovery, and (5) CS 3D T2-weighted. ADNI4 aims to help the neuroimaging community extract valuable imaging biomarkers and provide a database to test the impact of advanced imaging strategies on diagnostic accuracy and disease sensitivity among individuals lying on the cognitively normal to impaired spectrum. HIGHLIGHTS: A summary of MRI protocols for phase four of the Alzheimer's Disease Neuroimaging Initiative (ADNI 4). The design and justification for the ADNI 4 MRI protocols. Compressed sensing and multi-band advances have been applied to improve scan time. ADNI4 protocols aim to streamline safety screening and therapy monitoring. The ADNI4 database will be a valuable test bed for academic research.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11497751 | PMC |
http://dx.doi.org/10.1002/alz.14162 | DOI Listing |
Med Acupunct
August 2025
Department of Specialty Medicine, Ohio University, Athens, Ohio, USA.
Introduction: This review evaluates the safety protocols for acupuncture, emphasizing the need for stringent measures due to the procedure's invasive nature.
Discussion: It discusses the necessity of global safety standards, including mandatory accreditation and licensing for practitioners to mitigate risks such as needle contamination and improper technique. The study advocates for extensive training and continuous education programs to ensure practitioners master both theoretical and practical aspects of acupuncture.
NMR Biomed
October 2025
Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Understanding gastric physiology in rodents is critical for advancing preclinical neurogastroenterology research. However, existing techniques are often invasive, terminal, or limited in resolution. This study aims to develop a non-invasive, standardized MRI protocol capable of capturing whole-stomach dynamics in anesthetized rats with high spatiotemporal resolution.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Icon Cancer Centre Toowoomba, Toowoomba, Queensland, Australia.
Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.
Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.
Geroscience
September 2025
Department of Neurology, Albert Einstein College of Medicine, Bronx, NY, USA.
Cognitive decline is common in multiple sclerosis (MS), although neural mechanisms are not fully understood. The objective was to investigate the impact of mild cognitive impairment (MCI) on the relationship between resting state functional connectivity (RSFC) and cognitive function in older adults with multiple sclerosis (OAMS) and age matched healthy controls. Participants underwent magnetic resonance imaging (MRI) scans and cognitive assessments.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Department of Orthopaedics and Trauma Surgery, Orthopaedic Oncology, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to assess femoral and tibial torsion. While CT offers high spatial resolution, it involves ionizing radiation. MRI avoids radiation but requires multiple sequences and extended acquisition time.
View Article and Find Full Text PDF