Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: In patients with angina and non-obstructive coronary artery disease (ANOCA), diagnosis of coronary microvascular dysfunction (CMD) remains an unmet need. Magnetocardiography (MCG), is a rest-based, non-invasive scan that can detect weak electrophysiological changes that occur at the early phase of ischemia.
Objective: This study assessed the ability of MCG to detect CMD in ANOCA patients as compared to reference standard, invasive coronary flow reserve (CFR).
Methods: Patients with ANOCA and invasive coronary physiologic assessment using intracoronary flow measurements with Doppler and thermodilution methods were enrolled. CMD was defined dichotomously as an invasive CFR < 2.0 by Doppler or thermodilution assessment. Noninvasive 36-channel 90-s MCG scan was performed and quantitative assessment of four distinct MCG features was completed. We evaluated the diagnostic performance of 2 or more abnormal MCG features to detect CMD in the overall cohort and performed a subgroup analysis in the subset of patients with Doppler CFR assessment.
Results: Among 79 ANOCA patients, 25 were CMD positive and 54 patients were CMD negative by CFR. Using invasive CFR as reference, MCG had an ROC AUC of 0.66 with a sensitivity of 68 % and specificity of 65 % for the detection of CMD. In the subgroup with Doppler CFR assessment, MCG had an ROC AUC of 0.76 with a sensitivity of 75 % and specificity of 77 %.
Conclusions: In ANOCA patients, MCG demonstrates the ability to detect CMD using a 90-second non-invasive scan without the need for an intravenous stressor or ionizing radiation. Further investigations are needed to validate an MCG-based diagnostic pathway for CMD.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11301233 | PMC |
http://dx.doi.org/10.1016/j.ahjo.2024.100424 | DOI Listing |