A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of posture on position of subcutaneous implantable cardioverter-defibrillator. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The PRAETORIAN score was developed as an alternative for defibrillation testing after subcutaneous implantable cardioverter-defibrillator implantation to assess 3 aspects of implant position on a bidirectional chest radiograph. The score is validated on a standard standing chest radiograph with arms elevated in the lateral view.

Objective: We aimed to evaluate the effect of different anatomic positions on the PRAETORIAN score.

Methods: Thirty patients with a subcutaneous implantable cardioverter-defibrillator underwent standard posterior-anterior and lateral chest radiography, including additional lateral views in 2 positions: standing with arms down and supine with arms alongside the body. PRAETORIAN score and weighted κ coefficient were calculated for each position.

Results: In 8 of 30 patients, the PRAETORIAN score was ≥90 in standard position. The agreement in PRAETORIAN score was substantial (κ = 0.677) for the position with the arms down and fair (κ = 0.399) for the supine position. With the arms down, the PRAETORIAN score decreased in 10 patients (33%), 4 of whom changed to a lower risk category. In supine position, the PRAETORIAN score decreased in 16 patients (53%), 7 of whom changed to a lower risk category, 1 from high to low risk.

Conclusion: A supine or arms-down position during chest radiography can result in lower PRAETORIAN scores and underestimation of associated risk on defibrillation testing failure. This emphasizes the importance of correct anatomic positioning (arms up) during chest radiography when the PRAETORIAN score is used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2024.07.122DOI Listing

Publication Analysis

Top Keywords

praetorian score
28
subcutaneous implantable
12
implantable cardioverter-defibrillator
12
chest radiography
12
praetorian
9
score
8
defibrillation testing
8
chest radiograph
8
position arms
8
supine position
8

Similar Publications