Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Elbow stiffness is 1 of the most common complications after operative fixation of distal humerus fractures; however, there is relatively limited literature assessing which factors are associated with this problem. The purpose of this study is to identify risk factors associated with dysfunctional elbow stiffness in distal humerus fractures after operative fixation.

Methods: A retrospective review of all distal humerus fractures that underwent operative fixation (AO/OTA 13A-C) at a single level 1 trauma center from November 2014 to October 2021. A minimum 6-month follow-up was required for inclusion or the outcome of interest. Dysfunctional elbow stiffness was defined as a flexion-extension arc of less than 100° at latest follow-up or any patient requiring surgical treatment for limited elbow range of motion.

Results: A total of 110 patients with distal humerus fractures were included in the study: 54 patients comprised the elbow stiffness group and 56 patients were in the control group. Average follow-up of 343 (59 to 2079) days. Multiple logistic regression showed that orthogonal plate configuration (adjusted odds ratio [aOR]: 5.70, 95% confidence interval [CI]: 1.91-16.99, P = .002), and longer operative time (aOR: 1.86, 95% CI: 1.11-3.10, P = .017) were independently associated with an increased odds of elbow stiffness. OTA/AO 13A type fractures were significantly associated with a decreased odds of stiffness (aOR: 0.16, 95% CI: 0.03-0.80, P = .026). Among 13C fractures, olecranon osteotomy (aOR: 5.48, 95% CI: 1.08-27.73, P = .040) was also associated with an increased odds of elbow stiffness. There were no significant differences in injury mechanism, Gustilo-Anderson classification, reduction quality, days to surgery from admission, type of fixation, as well as rates of ipsilateral upper extremity fracture, neurovascular injury, nonunion, or infection between the 2 groups.

Conclusion: Dysfunctional elbow stiffness was observed in 49.1% of patients who underwent operative fixation of distal humerus fractures in the present study. Orthogonal plate configuration, olecranon osteotomy, and longer operative time were associated with increased odds of dysfunctional elbow stiffness; however, 13A type fractures were associated with decreased odds of stiffness. Patients with these injuries should be counseled on their risk of stiffness following surgery and modifiable risk factors like plate positioning and performing an olecranon osteotomy should be considered by surgeons.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2024.06.010DOI Listing

Publication Analysis

Top Keywords

elbow stiffness
36
distal humerus
24
humerus fractures
24
dysfunctional elbow
20
operative fixation
16
risk factors
12
stiffness
12
fixation distal
12
associated increased
12
increased odds
12

Similar Publications

Background: Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently, a dynamic tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation.

View Article and Find Full Text PDF

Objective: The treatment of severe post-traumatic elbow stiffness is extremely complex. Complete open release of the elbow joint and reconstruction of stiffness-related injuries are considered crucial; however, these procedures may lead to elbow instability, particularly chronic instability due to underlying conditions. This retrospective study aimed to assess the outcomes of using an internal joint stabilizer (IJS) to ensure post-release stability in these complex cases.

View Article and Find Full Text PDF

The results of our survey conducted among the members of the European Society for Surgery of the Shoulder and the Elbow is presented in this article. The two most important features of frozen shoulder are movement restriction and pain. Frozen shoulder is considered secondary if it occurs after surgery or trauma.

View Article and Find Full Text PDF

Does a counterforce brace reduce common extensor tendon loading during a wrist extension task? An in vivo study.

J Biomech

October 2025

Department of Physiotherapy, School of Allied Health, Auckland University of Technology, Auckland, New Zealand; Pain and Musculoskeletal Conditions Research Group, New Zealand.

This study assessed the biomechanical effect of a counterforce brace on the common extensor origin (CEO) tendon at the elbow via the measurement of shear wave velocity (SWV) using ultrasound. The counterforce brace was hypothesised to reduce SWV, which is a proxy measure of tendon stiffness, whilst the wrist and finger extensors were contracting at different levels of maximum voluntary contraction (MVC). In this cross-sectional study, nineteen healthy participants (age±SD: 30±9) were included in the study.

View Article and Find Full Text PDF

Background: Coronoid fractures significantly impact elbow stability, yet limited biomechanical data exists comparing fixation methods for different fracture types. This study aimed to compare the biomechanical performance of threaded K-wire versus cortical screw fixation in O'Driscoll type 2 and 3 coronoid fractures.

Methods: Twenty-eight synthetic ulnar bones were divided into four groups (n = 7 each): Type 2 with K-wire fixation, Type 2 with screw fixation, Type 3 with K-wire fixation, and Type 3 with screw fixation.

View Article and Find Full Text PDF