Background: Continuous-flow left ventricular assist device (cfLVAD) use is effective in supporting patients with end-stage heart failure (ESHF). Reduced flow pulsatility within the systemic circulation in cfLVAD-supported patients may lead to alterations within the microcirculation. Temporal changes in microvasculature in relation to adverse events in cfLVAD-supported patients have not been studied. We aimed to profile changes within retinal microvasculature and its association with adverse events.
Methods: Retinal photography was performed using Topcon TRC-NW8 nonmydriatic fundus camera in cfLVAD-supported patients and ESHF control patients. Specific retinal measurements were evaluated using a validated semiautomated program. Demographic and adverse event data were documented.
Results: Forty-eight patients were studied (n = 29 cfLVAD, n = 19 ESHF). There were significant trends in retinal arteriolar caliber (B = -0.53 µm, 95% confidence interval [CI]: -0.96 to -0.10, p = 0.016) and retinal fractal dimension parameters (B = 0.014, 95% CI: 0.001-0.002, p = 0.016) in linear mixed model regressions. Among cfLVAD patients, there was a significant association between the incidence of gastrointestinal bleeding and stepwise increases in retinal arteriolar-venular caliber ratio (hazard ratio: 3.03, 95% CI: 2.06-4.45, p = 0.005), a measure of arteriolar narrowing.
Conclusions: We have observed for the first time that alterations in retinal microvasculature in cfLVAD-supported patients may be associated with gastrointestinal bleeding. While understanding these temporal changes may predict future adverse events in cfLVAD-supported patients, further multicenter studies are required to confirm the associations observed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.healun.2024.07.017 | DOI Listing |
JHLT Open
November 2024
Heart Failure and Transplant Unit, St. Vincent's Hospital, Sydney, Australia.
Bleeding complications are a bane of continuous flow left ventricular assist devices (cfLVAD); gastrointestinal bleeding (GIB) from arteriovenous malformation (AVM) predominating. We hypothesized that shear stress disrupts vascular endothelium altering angiogenesis and contributing to bleeding. We profiled markers of endothelial dysfunction (soluble thrombomodulin [sTM]) and angiogenesis (angiopoietin-1 [Ang-1], angiopoietin-2 [Ang-2]) in 21 patients implanted with a centrifugal cfLVAD.
View Article and Find Full Text PDFJ Heart Lung Transplant
December 2024
University of New South Wales Sydney, Sydney, Australia; Department of Cardiology, Heart Failure and Transplant Unit, St. Vincent's Hospital Sydney, Sydney, Australia; Victor Chang Cardiac Research Institute, Sydney, Australia. Electronic address:
Background: Continuous-flow left ventricular assist device (cfLVAD) use is effective in supporting patients with end-stage heart failure (ESHF). Reduced flow pulsatility within the systemic circulation in cfLVAD-supported patients may lead to alterations within the microcirculation. Temporal changes in microvasculature in relation to adverse events in cfLVAD-supported patients have not been studied.
View Article and Find Full Text PDFInt J Artif Organs
July 2013
Heart Failure and Transplant Unit, St Vincent's Hospital Sydney, Sydney, Australia.
Background: Continuous flow left ventricular assist devices (cfLVADs) are used in clinical practice for the management of end-stage heart failure. Axial flow cfLVADS have been associated with increased rates of adverse gastrointestinal events such as bleeding angiodysplasia. The purpose of this study was to determine the incidence of bleeding gastrointestinal tract angiodysplasia and the profile of patients supported with the centrifugal cfLVAD, referred for endoscopy.
View Article and Find Full Text PDF