A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Impact of Centrifugation Parameters on Platelet-Rich Plasma Injection for Patella Tendinopathy: A Systematic Review and Meta-Analysis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Patellar tendinopathy (PT) is a chronic, degenerative form of tendinitis commonly affecting young, active individuals. Numerous nonsurgical treatments exist, of which platelet-rich plasma (PRP) is a frontrunner. However, heterogeneity among various PRP preparation techniques results in a large variation in treatment efficacy. This review and meta-analysis aims to investigate the effect of PRP centrifugation factors, specifically centrifuge speed and duration, on functional outcomes in patients with PT. A systematic search of the literature was performed in April 2024 on Medline and Embase. Articles involving the use of PRP in the treatment of PT were included. The risk of bias was assessed using the Risk of Bias 2 (RoB 2; the Cochrane Collaboration, England, UK) and Risk of Bias in Non-randomised Studies of Intervention (ROBINS-I; the Cochrane Collaboration, England, UK) tools. Comparative meta-analysis between the different centrifugation speeds and the different centrifugation durations was performed on articles reporting Victorian Institute of Sports Assessment - Patellar tendon (VISA-P) and visual analogue scale (VAS) scores for PT. Seventeen studies consisting of 360 participants were included in the analysis. The mean follow-up duration was 13.2 months (95% CI: 8.81 to 17.7). The mean VAS reduction was 3.85 (95% CI: -4.63 to -3.08; P < 0.01). VISA-P scores improved by 32.03 (95% CI: 24.29 to 39.78; P < 0.01). There were no significant differences between centrifuge speeds for VAS (P = 0.17) and VISA-P (P = 0.18) and between centrifuge durations for VAS (P = 0.25) and VISA-P (P = 0.27). Centrifuge speed and duration and number of centrifuge cycles did not show any significant differences in patient outcomes. There were no significant differences observed in outcomes for the different preparations of PRP. There remains a need for further high-quality RCTs using standardized PRP preparations with long-term follow-up for the development of a consensus method of PRP preparation for the treatment of PT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11283629PMC
http://dx.doi.org/10.7759/cureus.63341DOI Listing

Publication Analysis

Top Keywords

risk bias
12
platelet-rich plasma
8
review meta-analysis
8
prp preparation
8
centrifuge speed
8
speed duration
8
cochrane collaboration
8
collaboration england
8
prp
7
centrifuge
5

Similar Publications