Article Abstract

Cortisol is a clinically validated stress biomarker that takes part in many physiological and psychological functions related to the body's response to stress factors. In particular, it has emerged as a pivotal tool for understanding stress levels and overall well-being. Usually, in clinics, cortisol levels are monitored in blood or urine, but significant changes are also registered in sweat and saliva. In this work, a surface plasmon resonance probe based on a D-shaped plastic optical fiber was functionalized with a glucocorticoid receptor exploited as a highly efficient bioreceptor specific to cortisol. The developed plastic optical fiber biosensor was tested for cortisol detection in buffer and artificial saliva. The biosensor response showed very good selectivity towards other hormones and a detection limit of about 59 fM and 96 fM in phosphate saline buffer and artificial saliva, respectively. The obtained detection limit, with a rapid detection time (about 5 min) and a low-cost sensor system, paved the way for determining the cortisol concentration in saliva samples without any extraction process or sample pretreatment via a point-of-care test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11274917PMC
http://dx.doi.org/10.3390/bios14070351DOI Listing

Publication Analysis

Top Keywords

plastic optical
12
optical fiber
12
cortisol detection
8
buffer artificial
8
artificial saliva
8
detection limit
8
cortisol
6
detection
5
saliva
5
efficient bio-receptor
4

Similar Publications

Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.

Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.

View Article and Find Full Text PDF

Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.

Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation).

View Article and Find Full Text PDF

Purpose: To quantify and compare the cost, waste, and carbon emissions of single-use and reusable phacoemulsification tubing/cassettes and knives.

Setting: Private, single-specialty ambulatory surgery center (Mountain View, CA, USA).

Design: Retrospective data review.

View Article and Find Full Text PDF

Single-cell transcriptome combined with genetic tracing reveals a roadmap of fibrosis formation during proliferative vitreoretinopathy.

Proc Natl Acad Sci U S A

September 2025

Department of Ophthalmology, Tianjin Medical University General Hospital, International Joint Laboratory of Ocular Diseases (Ministry of Education), State Key Laboratory of Experimental Hematology, Tianjin Key Laboratory of Ocular Trauma, Laboratory of Molecular Ophthalmology, Tianjin Medical Univer

Ocular fibrosis, a severe consequence of excessive retinal wound healing, can lead to vision loss following retinal injury. Proliferative vitreoretinopathy (PVR), a common form of ocular fibrosis, is a major cause of blindness, characterized by the formation of extensive fibrous proliferative membranes. Understanding the cellular origins of PVR-associated fibroblasts (PAFs) is essential to decipher the mechanisms of ocular wound healing.

View Article and Find Full Text PDF

"Reconstruction of Large Full-Thickness Medial Lower Eyelid Defects Using a Medially-Based Tarsoconjunctival Pedicle Flap".

Plast Reconstr Surg

September 2025

Division of Oculofacial Plastic and Reconstructive Surgery, Viterbi Family Department of Ophthalmology, UC San Diego Shiley Eye Institute, La Jolla, CA, USA.

Reconstruction of large full-thickness medial lower eyelid margin defects often requires centrally-based tarsoconjunctival pedicle flaps from the ipsilateral upper eyelid in combination with anterior lamellar grafting. However, centrally-based flaps may result in temporary obstruction of the visual axis in the affected eye. We present a novel modified surgical technique utilizing a medially-based tarsoconjunctival pedicle flap from the upper eyelid for the reconstruction of large full-thickness medial lower eyelid defects.

View Article and Find Full Text PDF