Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning.

Biosensors (Basel)

Department of Laboratory Medicine, College of Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.

Published: July 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The COVID-19 pandemic has highlighted the urgent need for rapid and accurate diagnostic methods for various infectious diseases, including SARS-CoV-2. Traditional RT-PCR methods, while highly sensitive and specific, require complex equipment and skilled personnel. In response, we developed an integrated RT-LAMP-MS assay, which combines rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) with microscanning (MS) technology for detecting SARS-CoV-2. The assay uses magnesium pyrophosphate formed during LAMP amplification as a visual marker, allowing direct observation via microscopy without the need for additional chemical indicators or probes. For the SARS-CoV-2/IC RT-LAMP-MS assay, the sample-LAMP reagent mixture was added to a microchip with SARS-CoV-2 primers and internal controls, then incubated at 62 °C for 30 min in a heat block, followed by amplification analysis using a microscanner. In clinical tests, the RT-LAMP-MS assay showed 99% sensitivity and 100% specificity, which is identical to the RT-LAMP results and comparable to the commercial Allplex SARS-CoV-2 assay results. Additionally, the limit of detection (LOD) was determined to be 10 PFU mL (dynamic range: 10~10 PFU mL). The assay delivers results in 30 min, uses low-cost equipment, and demonstrates 100% reproducibility in repeated tests, making it suitable for point-of-care use in resource-limited settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11274610PMC
http://dx.doi.org/10.3390/bios14070348DOI Listing

Publication Analysis

Top Keywords

rt-lamp-ms assay
12
rt-lamp microscanning
8
sars-cov-2 assay
8
assay
6
sars-cov-2
5
enhanced point-of-care
4
point-of-care sars-cov-2
4
sars-cov-2 detection
4
detection integrating
4
integrating rt-lamp
4

Similar Publications

Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning.

Biosensors (Basel)

July 2024

Department of Laboratory Medicine, College of Medicine, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea.

The COVID-19 pandemic has highlighted the urgent need for rapid and accurate diagnostic methods for various infectious diseases, including SARS-CoV-2. Traditional RT-PCR methods, while highly sensitive and specific, require complex equipment and skilled personnel. In response, we developed an integrated RT-LAMP-MS assay, which combines rapid reverse transcription loop-mediated isothermal amplification (RT-LAMP) with microscanning (MS) technology for detecting SARS-CoV-2.

View Article and Find Full Text PDF