A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Analytical and Clinical Validation of a Non-Ristocetin Based VWF Assay on 2 Automated Analyzers in a Large Reference Laboratory. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Historically, von Willebrand factor (VWF) activity assays utilized ristocetin despite limitations including poor limits of detection and high imprecision. Newer VWF activity assays such as the INNOVANCE® VWF Ac assay, however, do not rely on ristocetin to measure platelet-dependent VWF function. The purpose of this study was to evaluate the analytical and clinical performance of the Siemens Healthineers INNOVANCE VWF Ac Assay on the Siemens BCS® XP and the Sysmex® CS-2500 systems in a large reference laboratory setting.

Methods: Performance indicators for the INNOVANCE VWF Ac assay were the limit of quantitation (LoQ), precision, and method comparison. Method comparison studies were performed using remnant plasma patient samples from routine coagulation tests and analyzed using both the INNOVANCE VWF Ac assay and the Siemens Healthineers ristocetin-dependent BC von Willebrand Reagent.

Results: Evaluation of the INNOVANCE VWF Ac assay on the BCS® XP and CS-2500 systems demonstrated good precision and a lower LoQ compared to the BC von Willebrand Reagent. Method comparisons support the use of the INNOVANCE VWF Ac assay on the BCS® XP and CS-2500 systems to measure platelet-dependent VWF function. The INNOVANCE VWF Ac assay was able to further assist in von Willebrand disease classification in 6/7 (86%) samples when the result was below the LoQ for the BC von Willebrand Reagent (ristocetin cofactor activity).

Conclusions: These data are consistent with the 2021 American Society of Hematology/International Society on Thrombosis and Haemostasis/National Hemophilia Foundation/World Federation of Hemophilia von Willebrand disease guidelines that suggest using newer assays such as the INNOVANCE VWF Ac assay in place of ristocetin cofactor activity assays.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jalm/jfae063DOI Listing