Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Aims: Cardiac magnetic resonance (CMR) imaging is a main diagnostic tool in the follow-up of Fontan patients. However, the value of serial CMR for the evaluation of Fontan attrition is unknown. The aim of this prospective study of serial CMR is to describe the analysis of time-dependent evolution of blood flow distribution, ventricular volumes, and function in patients after Fontan completion.
Methods And Results: In this prospective single-centre study, between 2012 and 2022, 281 CMR examinations were performed in 88 Fontan patients with distribution of blood flows, measurements of ventricular volumes, and ejection fraction. Linear mixed model regression for repeated measurements was used to analyse changes of measurements across serial CMR examinations. During a time interval of 10 years, the median number of CMR per patient was 3 (range 1-5). Indexed flow of ascending aorta, caval veins, and pulmonary arteries decreased significantly across serial CMR examinations. Although a decrease of mean indexed aortic flow (3.03 ± 0.10 L/min/m at first CMR vs. 2.36 ± 0.14 L/min/m at fourth CMR, < 0.001) was observed, ejection fraction did not decline (50 ± 1% at first CMR vs. 54 ± 2% at fourth CMR, = 0.070). Indexed ventricular volumes did not differ significantly across serial CMR examinations.
Conclusion: The decrease of indexed aortic and cavopulmonary flows reflects the attrition of univentricular circulation and can be detected by means of serial CMR. Ventricular systolic dysfunction does not contribute significantly to this attrition. In order to detect significant change of indexed aortic flow, we recommend performing serial CMR as routine practice in the Fontan population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195729 | PMC |
http://dx.doi.org/10.1093/ehjimp/qyad039 | DOI Listing |