Evaluating the Accuracy and Impact of the ESR-iGuide Decision Support Tool in Optimizing CT Imaging Referral Appropriateness.

J Imaging Inform Med

School of Health Professions, Faculty of Medical & Health Sciences, Tel-Aviv University, Tel-Aviv-Yafo, Israel.

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Radiology referral quality impacts patient care, yet factors influencing quality are poorly understood. This study assessed the quality of computed tomography (CT) referrals, identified associated characteristics, and evaluated the ESR-iGuide clinical decision support tool's ability to optimize referrals. A retrospective review analyzed 300 consecutive CT referrals from an acute care hospital. Referral quality was evaluated on a 5-point scale by three expert reviewers (inter-rater reliability κ = 0.763-0.97). The ESR-iGuide tool provided appropriateness scores and estimated radiation exposure levels for the actual referred exams and recommended exams. Scores were compared between actual and recommended exams. Associations between ESR-iGuide scores and referral characteristics, including the specialty of the ordering physician (surgical vs. non-surgical), were explored. Of the referrals, 67.1% were rated as appropriate. The most common exams were head and abdomen/pelvis CTs. The ESR-iGuide deemed 70% of the actual referrals "usually appropriate" and found that the recommended exams had lower estimated radiation exposure compared to the actual exams. Logistic regression analysis showed that non-surgical physicians were more likely to order inappropriate exams compared to surgical physicians. Over one-third of the referrals showed suboptimal quality in the unstructured system. The ESR-iGuide clinical decision support tool identified opportunities to optimize appropriateness and reduce radiation exposure. Implementation of such a tool warrants consideration to improve communication and maximize patient care quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11811312PMC
http://dx.doi.org/10.1007/s10278-024-01197-5DOI Listing

Publication Analysis

Top Keywords

decision support
12
radiation exposure
12
recommended exams
12
support tool
8
referral quality
8
patient care
8
esr-iguide clinical
8
clinical decision
8
estimated radiation
8
compared actual
8

Similar Publications

Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.

Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.

View Article and Find Full Text PDF

Background: Recent advances in high-throughput sequencing technologies have enabled the collection and sharing of a massive amount of omics data, along with its associated metadata-descriptive information that contextualizes the data, including phenotypic traits and experimental design. Enhancing metadata availability is critical to ensure data reusability and reproducibility and to facilitate novel biomedical discoveries through effective data reuse. Yet, incomplete metadata accompanying public omics data may hinder reproducibility and reusability and limit secondary analyses.

View Article and Find Full Text PDF

Purpose: To clinically validate the nursing diagnosis "Inadequate Nutritional Intake" based on elements identified within a specific situation theory framework in the context of children with cancer.

Methods: This is a diagnostic accuracy study following the Standards for Reporting Diagnostic Accuracy Studies (STARD) protocol. Specifically, it refers to the clinical validation phase of the nursing diagnosis Inadequate nutritional intake, using a cross-sectional design.

View Article and Find Full Text PDF

Purpose: Amino acid PET with [F]-fluoroethylthyrosine ([F]FET-PET) is frequently utilized in gliomas. Most studies on prognostication based on amino acid PET comprise mixed cohorts of brain tumors with low- and high-grade features. The objective of this study was to assess the potential prognostic value of [F]FET-PET-based markers in the group of grade 2 adult-type diffuse gliomas, as defined by the WHO CNS 2021 classification.

View Article and Find Full Text PDF

The WHO global landscape of cancer clinical trials.

Nat Med

September 2025

Emerging Technology, Research Prioritization and Support Unit, Department of Research for Health, World Health Organization, Geneva, Switzerland.

Clinical trials are essential to advancing cancer control, yet access and participation remain unequal globally. The World Health Organization (WHO) established the International Clinical Trials Registry Platform (ICTRP) to enable a complete view of interventional clinical research for all those involved in healthcare decision-making and to identify actionable goals to equitable participation at the global level. A review of 89,069 global cancer clinical trials registered in the WHO ICTRP between 1999 and December 2022 revealed a cancer clinical trial landscape dominated by high-income countries and focused on pharmacological interventions, with multinational collaboration limited to only 3% of recruiting trials.