A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Conservative method for vertical electrooculogram attenuation based on local suppression of ongoing EEG artifact templates. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Eye movement during blinking can be a significant artifact in Event-Related Potentials (ERP) analysis. Blinks produce a positive potential in the vertical electrooculogram (VEOG), spreading towards the posterior direction. Two methods are frequently used to suppress VEOGs: linear regression to subtract the VEOG signal from the electroencephalogram (EEG) and Independent Component Analysis (ICA). However, some information is lost in both. The present algorithm (1) statistically identifies the position of VEOGs in the frontopolar channels; (2) performs EEG averaging for each channel, which results in 'blink templates'; (3) subtracts each template from the respective EEG at each VEOG position, only when the linear correlation index between the template and the segment is greater than a chosen threshold L. The signals from twenty subjects were acquired using a behavioral test and were treated using FilterBlink for subsequent ERP analysis. A model was designed to test the method for each subject using twenty copies of the EEG signal from the subject's mid-central channel (with nearly no VEOG) representing the EEG channels and their respective blink templates. At the same 200 equidistant time points (marks), a signal (2.5 sinusoidal cycles at 1050 ms emulating an ERP) was mixed with each model channel and the respective blink template of that channel, between 500 to 1200 ms after each mark. According to the model, VEOGs interfered with both ERPs and the ongoing EEG, mainly on the anterior medial leads, and no significant effect was observed on the mid-central channel (Cz). FilterBlink recovered approximately 90% (Fp1) to 98% (Fz) of the original ERP and EEG signals for L = 0.1. The method reduced the VEOG effect on the EEG after ERP and blink-artifact averaging in analyzing real signals. The method is straightforward and effective for VEOG attenuation without significant distortion in the EEG signal and embedded ERPs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11257361PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0305902PLOS

Publication Analysis

Top Keywords

eeg
10
vertical electrooculogram
8
ongoing eeg
8
erp analysis
8
eeg signal
8
mid-central channel
8
respective blink
8
signals method
8
veog
6
erp
5

Similar Publications