Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Introduction: Despite anti-inflammatory reliever (AIR) therapy now being the preferred treatment choice across all severities of asthma, many patients are still "attached" to their short-acting beta-agonist (SABA) reliever, believing this to be the best way to control their asthma. To encourage individuals to switch to AIR, it is important to first identify the beliefs that patients hold about AIR.
Objective: The aim of this paper was to describe the initial development and validation of the BMQ-AIR, a six-item screening tool which assesses and identifies patients' treatment beliefs about switching to AIR therapy.
Methods: Statements were identified from the primary literature that assessed patients' perceptions of AIR therapy and adapted from the Beliefs about Medicines Questionnaire (BMQ). Internal reliability was examined using Cronbach's alpha coefficient. Construct validity was evaluated by comparing scores on BMQ-AIR with a validated measure of medication adherence and SABA beliefs.
Results: A total of 446 participants completed the online survey. The BMQ-AIR contained two subscales with three items each. Both the Necessity and Concerns subscales demonstrated good internal reliability, with Cronbach's α-values of 0.70 and 0.69, respectively. Both subscales were negatively correlated with self-report inhaled corticosteroid adherence (Necessity: r = -0.28, < 0.0001; Concerns: r = -0.28, < 0.0001) and positively correlated with SRQ scores (Necessity: r = 0.51, < 0.0001; Concerns: r = 0.44, < 0.0001).
Conclusion: Preliminary findings indicate that BMQ-AIR demonstrates satisfactory reliability and validity. BMQ-AIR is a promising tool that may help tailor interventions to an individual's specific beliefs and barriers to switching to better support individuals in stopping SABA and initiating AIR therapy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11239962 | PMC |
http://dx.doi.org/10.3389/fphar.2024.1351851 | DOI Listing |