Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The accuracy of multiparametric magnetic resonance imaging (mpMRI) heavily relies on image quality, as evidenced by the evolution of the prostate imaging quality (PI-QUAL) scoring system for the evaluation of clinically significant prostate cancer (csPC). This study aims to evaluate the impact of PI-QUAL scores in detecting csPC within PI-RADS 4 and 5 lesions. We retrospectively selected from our database all mpMRI performed from January 2019 to March 2022. Inclusion criteria were as follows: (1) mpMRI acquired in our institution according to the technical requirements from the PI-RADS (v2.1) guidelines; (2) single lesion scored as PI-RADS (v2.1) 4 or 5; (3) MRI-TBx performed in our institution; (4) complete histology report; and (5) complete clinical record. A total of 257 male patients, mean age 70.42 ± 7.6 years, with a single PI-RADS 4 or 5 lesion undergoing MRI-targeted biopsy, were retrospectively studied. Of these, 61.5% were PI-RADS 4, and 38.5% were PI-RADS 5, with 84% confirming neoplastic cells. In high-quality image lesions (PI-QUAL ≥ 4), all PI-RADS 5 lesions were accurately identified as positive at the final histological examination (100% of CDR). For PI-RADS 4 lesions, 37 (23%) were negative, resulting in a cancer detection rate of 77% (95% CI: 67.51-84.83). The accuracy of mpMRI, independently of the PI-RADS score, progressively decreased according to the decreasing PI-QUAL score. These findings emphasize the crucial role of the PI-QUAL scoring system in evaluating PI-RADS 4 and 5 lesions, influencing mpMRI accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11242596 | PMC |
http://dx.doi.org/10.3390/jcm13133785 | DOI Listing |