98%
921
2 minutes
20
A finite element model based on elastic-plastic theory was conducted to study the densification process of iron-based powder metallurgy during high velocity compaction (HVC). The densification process of HVC at different heights was simulated using MSC Marc 2020 software with the Shima-Oyane model, and compared with the experimental results. The numerical simulation results were consistent with the experimental results, proving the reliability of the finite element model. Through finite element analysis and theoretical calculation, the high-speed impact molding process of metal powder was analyzed, and the optimal empirical compaction equation for iron-based powder high-speed impact molding was obtained. At the same time, the influence of impact velocity and impact energy on the relative density distribution cloud map and numerical values of the compact was analyzed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11242827 | PMC |
http://dx.doi.org/10.3390/ma17133085 | DOI Listing |
BMC Oral Health
September 2025
Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany.
Background: A modified pull-through approach represents a promising treatment strategy to access tumors in the posterior oral cavity. The design of the wedge osteotomy plays a key role in preserving postoperative mechanical stability while enabling surgical access. However, the optimal osteotomy design to reduce fracture risk remains unclear.
View Article and Find Full Text PDFObjectives: Cervical cancer is a serious threat to women's life and health and has a high mortality rate. Colposcopy is an important method for early clinical cervical cancer screening, but the traditional vaginal dilator has problems such as discomfort in use and cumbersome operation. For this reason, this study aims to design an intelligent vaginal dilatation system to automate colposcopy and enhance patient comfort.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:
This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Centre for Biomechanics and Rehabilitation Technologies, Staffordshire University, Stoke-On-Trent, UK; Reading Central PCN, Reading, UK.
Background: Drape-forming is a cost-effective method used worldwide to manufacture bespoke ankle foot orthoses (AFOs). It involves draping a heated polymer material sheet over a positive cast of the user's limb. Previous research has shown that the manual nature of drape-forming can influence the thickness of the final AFO and even lead to structures that are inadequately rigid to be clinically effective.
View Article and Find Full Text PDFMed Eng Phys
October 2025
Department of Engineering Science, University of Oxford, United Kingdom. Electronic address:
Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).
View Article and Find Full Text PDF