A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Methods, precision, and analytical sensitivity of a novel low-plasma-volume assay of fibrinolytic capacity utilizing the euglobulin fraction. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Fibrinolysis is a critical aspect of the hemostatic system, with assessment of fibrinolytic potential being critical to predict bleeding and clotting risk. We describe the method for a novel low-plasma-volume assay of fibrinolytic capacity utilizing the euglobulin fraction (the "modified mini-euglobulin clot lysis assay [ECLA]"), its analytic sensitivity to alterations in key fibrinolytic substrates/regulators, and its initial applications in acute and convalescent disease cohorts.

Methods: The modified mini-ECLA requires 50 μL of plasma, a maximal read time of 3 h (with most results available within 60 min), and is entirely performed in a 96-well microplate. Assay measurements were obtained in a variety of commercial control and deficient plasmas representing clinically relevant hypo- and hyperfibrinolytic states, and in three distinct adolescent cohorts with acute or convalescent illness: critically ill, following endotracheal intubation; acute COVID-19-related illness; and ambulatory, 3 months following a venous thromboembolic event.

Results: In 100% and 75% deficient plasmas, hypofibrinolysis for plasminogen-deficient, fibrinolysis for alpha-2-antiplasmin-deficient, and hyperfibrinolysis for plasminogen activator inhibitor-1-deficient plasmas were observed.

Conclusion: The modified mini-ECLA Clot Lysis Time Ratio ("CLTR") demonstrated moderate-strength correlations with the Clot Formation and Lysis (CloFAL) assay, is analytically sensitive to altered fibrinolytic states in vitro, and correlates with clinical outcomes in preliminarily-studied patient populations.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ijlh.14340DOI Listing

Publication Analysis

Top Keywords

novel low-plasma-volume
8
low-plasma-volume assay
8
assay fibrinolytic
8
fibrinolytic capacity
8
capacity utilizing
8
utilizing euglobulin
8
euglobulin fraction
8
clot lysis
8
acute convalescent
8
modified mini-ecla
8

Similar Publications