T1 mapping: a non-invasive tool to assess the systemic right ventricle.

Int J Cardiovasc Imaging

Department of Pediatrics, Heart Institute, UPMC Children's Hospital of Pittsburgh, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.

Published: August 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ventricular remodeling leads to fibrotic changes in systemic right ventricles (RV). Native T1 mapping provides a quantitative measure in myocardial tissue characterization. The aim of our study was to correlate native T1 values of the systemic RV to function and volumetric data. Native T1 maps were generated with a single breath hold Modified Look-Locker Inversion-recovery pulse (MOLLI) sequence was acquired in the mid-ventricular short axis. Regions of interest (ROI) were drawn in both ventricular free walls, the interventricular septum (IVS), superior insertion point (SIP) and inferior insertion point (IIP) to obtain native T1 values. T1 values were compared to CMR ventricular volumes and function using Spearman correlation. The median age was 36 years (IQR 27-48 years). There were elevated mean native left ventricular (LV) T1 and IIP T1 values at 1122 ± 171 ms and 1117 ± 96 ms, respectively. RV dysfunction was associated with elevated IIP T1 (p = 0.007). Significant moderate negative correlations were seen between RV T1 and LV ejection fraction (LVEF) (r= -0.63, p = 0.01), between RV: IVS T1 ratio and LVEF (r= -0.68, p = 0.006), between LVEF and SIP: IVS T1 ratios (r= -0.54, p = 0.04), and RVEF and IIP T1 (r= -0.59, p = 0.02). Fibrosis measured by native T1 mapping in the systemic RV is most prominent in the LV wall and septal insertion point and correlates with decreased function. T1 values can be used in non-invasive imaging assessment of the RV, but further studies with larger cohorts are needed to assess ability to risk stratify and guide therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11819913PMC
http://dx.doi.org/10.1007/s10554-024-03168-xDOI Listing

Publication Analysis

Top Keywords

insertion point
12
native mapping
8
native values
8
native
6
values
5
mapping non-invasive
4
non-invasive tool
4
tool assess
4
systemic
4
assess systemic
4

Similar Publications

Purpose: To evaluate changes in implant stability quotient values of hydrophilic tissue-level implants over time, and to investigate the influence of local factors on variations in these values.

Methods: Fifty tapered, self-tapping, tissue-level implants with a hydrophilic surface were placed and monitored for 12 months. Implant stability quotient values were recorded at the time of insertion (T0) and monthly thereafter for 12 months.

View Article and Find Full Text PDF

Sickle cell disease (SCD) is an inherited blood disorder marked by the production of abnormal hemoglobin, leading to the distortion-or sickling-of red blood cells. The SCD arises from a single-point mutation that substitutes glutamic acid with valine at the sixth codon of the β-globin chain in hemoglobin. This substitution promotes deoxyhemoglobin aggregation, elevating red blood cell stiffness, and triggering vaso-occlusive and hemolytic repercussions.

View Article and Find Full Text PDF

Background: The limited workspace and strong magnetic field inside MRI challenge the design of the prostate puncture robot. Simplifying the robot's structure is crucial.

Methods: This paper proposes a parallel cable-driven (PCD) prostate puncture robot, and conducts a preliminary material design.

View Article and Find Full Text PDF

Background: Patients with secondary hip osteoarthritis due to developmental dysplasia of the hip (DDH) often have abnormal femoral morphology, making stem design critical for long-term outcomes. The FMS-anatomic stem previously demonstrated favourable mid-term results. Its successor, the Anatomic Fit stem, was developed with a reduced hydroxyapatite-coated area to enhance proximal load transfer and a narrower lateral flare to facilitate insertion.

View Article and Find Full Text PDF

Dynamic joint balancing (DJB) in robotic-assisted total knee arthroplasty (RATKA) allows surgeons to simulate implant positioning and predict soft tissue balance intraoperatively before bone resection. Although virtual gap (VG) estimation is integral to this process, its accuracy in predicting the final gap (FG) after implantation remains uncertain. We conducted a retrospective analysis of 77 knees in 61 patients undergoing RATKA with the MAKO system.

View Article and Find Full Text PDF