Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Partial-thickness corneal transplants using a deep anterior lamellar keratoplasty (DALK) approach has demonstrated better patient outcomes than a full-thickness cornea transplant. However, despite better clinical outcomes from the DALK procedure, adoption of the technique has been limited because the accurate insertion of the needle into the deep stroma remains technically challenging. In this work, we present a novel hands-free eye mountable robot for automatic needle placement in the cornea, AutoDALK, that has the potential to simplify this critical step in the DALK procedure. The system integrates dual light-weight linear piezo motors, an OCT A-scan distance sensor, and a vacuum trephine-inspired design to enable the safe, consistent, and controllable insertion of a needle into the cornea for the pneumodissection of the anterior cornea from the deep posterior cornea and Descemet's membrane. AutoDALK was designed with feedback from expert corneal surgeons and performance was evaluated by finite element analysis simulation, benchtop testing, and ex vivo experiments to demonstrate the feasibility of the system for clinical applications. The mean open-loop positional deviation was 9.39 µm, while the system repeatability and accuracy were 39.48 µm and 43.18 µm, respectively. The maximum combined thrust of the system was found to be 1.72 N, which exceeds the clinical penetration force of the cornea. In a head-to-head ex vivo comparison against an expert surgeon using a freehand approach, AutoDALK achieved more consistent needle depth, which resulted in fewer perforations of Descemet's membrane and significantly deeper pneumodissection of the stromal tissue. The results of this study indicate that robotic needle insertion has the potential to simplify the most challenging task of the DALK procedure, enable more consistent surgical outcomes for patients, and standardize partial-thickness corneal transplants as the gold standard of care if demonstrated to be more safe and more effective than penetrating keratoplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11205909PMC
http://dx.doi.org/10.3390/mi15060788DOI Listing

Publication Analysis

Top Keywords

dalk procedure
12
eye mountable
8
deep anterior
8
anterior lamellar
8
lamellar keratoplasty
8
partial-thickness corneal
8
corneal transplants
8
insertion needle
8
potential simplify
8
descemet's membrane
8

Similar Publications

Corneal transplantation wound dehiscence after penetrating keratoplasty and deep anterior lamellar keratoplasty.

Int Ophthalmol

September 2025

Department of Ophthalmology and Visual Sciences, Carver College of Medicine, University of Iowa, 200 Hawkins Dr, 11290A PFP, Iowa City, IA, 52242, USA.

Purpose: To study clinical characteristics and outcomes of penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK) wound dehiscence.

Methods: This retrospective case series assessed PK and DALK recipients with wound dehiscence at a single institution. We evaluated relationships between dehiscence etiologies, transplant indications, ocular/systemic comorbidities, keratoplasty type, and adverse post-dehiscence outcomes, especially graft failure and visual loss.

View Article and Find Full Text PDF

Purpose: To evaluate the long-term visual, functional outcomes, and complications associated with Deep Anterior Lamellar Keratoplasty (DALK) in pediatric keratoconus (KC).

Methods: A retrospective analysis of children aged ≤18 years who underwent DALK for KC between February 2006 and April 2021. Data on preoperative uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), corneal topography, surgical technique, and complications.

View Article and Find Full Text PDF

Aim: The purpose of this study is to investigate the accuracy of intraocular lens (IOL) power calculation after penetrating keratoplasty (PK) or deep anterior lamellar keratoplasty (DALK) and to identify the causes of predictive errors (PEs) in relation to the subjective keratometric (K) value (SK) in eyes with corneal multifocality.

Methods: This retrospective study included 74 eyes that underwent cataract surgery after PK or DALK. PEs were compared between SRK/T, Haigis, Barrett Universal II (BUII) and Kane formulas.

View Article and Find Full Text PDF

Purpose: To investigate the influence of perforation of Descemet membrane (DM) on graft survival outcomes during deep anterior lamellar keratoplasty (DALK) for treating keratoconus.

Methods: We retrospectively reviewed 81 eyes of 77 patients with keratoconus who underwent deep anterior lamellar keratoplasty (DALK). Graft survival, best spectacle-corrected visual acuity (BSCVA), corneal endothelial cell density, and postoperative complications were compared between eyes with and without intraoperative Descemet membrane (DM) perforations.

View Article and Find Full Text PDF

To compare efficacy and safety for deep anterior lamellar keratoplasty (DALK) versus penetrating keratoplasty (PK) for macular corneal dystrophy. Following PRISMA guidelines, we searched four electronic databases (PubMed, Scopus, Cochrane Library, and Web of Science) to identify eligible studies reported up to January 2024. Using STATA 17, we reported outcomes as log risk ratios (log RRs) or mean difference (SMD) and confidence intervals (CIs).

View Article and Find Full Text PDF