A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of Pre-Transfusion Crossmatch Test Using Microscanner C3. | LitMetric

Evaluation of Pre-Transfusion Crossmatch Test Using Microscanner C3.

Diagnostics (Basel)

Departments of Laboratory Medicine, College of Medicine, Korea University, Seoul 02841, Republic of Korea.

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A pre-transfusion crossmatch test is crucial for ensuring safe blood transfusions by identifying the compatibility between donor and recipient blood samples. Conventional tube methods for crossmatching have limitations, including subjectivity in result interpretation and the potential for human error. In this study, we evaluated the diagnostic performance of a new crossmatch test using Microscanner C3, which can overcome these shortcomings. The crossmatch test results using the method were obtained in 323 clinical samples. The sensitivity, specificity, positive predictive value, negative predictive value, and concordance rate of the crossmatch test using Microscanner C3 were 98.20%, 100.00%, 100.00%, 98.11%, and 99.07%, respectively. The diagnostic performance of the new system offers a promising alternative to conventional tube methods for pre-transfusion crossmatch testing. Microscanner C3 could also increase the automation, standardization, and accuracy of crossmatch tests. The crossmatch test using Microscanner C3 is thought to increase the efficiency and reliability in identifying blood samples suitable for transfusion, thereby improving patient safety and optimizing the use of blood products in clinical settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11202519PMC
http://dx.doi.org/10.3390/diagnostics14121231DOI Listing

Publication Analysis

Top Keywords

crossmatch test
24
test microscanner
16
pre-transfusion crossmatch
12
crossmatch
8
blood samples
8
conventional tube
8
tube methods
8
diagnostic performance
8
test
6
microscanner
5

Similar Publications