A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Analytical QbD for the optimization of a multimode HPLC method for the investigation of hydrochlorothiazide, diltiazem and propranolol release from 3D printed formulation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Since 3D printing technology is an emerging field in pharmaceutical technology, the present study aimed at the development of a mixed-mode liquid chromatographic method for the separation and determination of hydrochlorothiazide, diltiazem, and propranolol to investigate their in-vitro release performance from 3D printed tablets. Due to the unique properties of the mixed-mode stationary phase, the three drugs were separated in less than 8 min under isocratic elution. Method development was accomplished following the Analytical Quality by Design principles and was evaluated using risk assessment and multivariate analysis. The influences of critical method parameters on critical method attributes (were screened using a 2-level fractional factorial design and subsequently optimized through a central composite design. The method operable design region was approved by the establishment of a robust zone using Monte Carlo simulation and capability analysis. The validation of the HPLC method was performed based on the total error concept. The relative bias was varied between ─ 11.6 % and 10.5 % and the RSD values for repeatability and intermediate precision were below 4.4 % in all cases. The limits of detection (LOD) ranged between 0.17 - 0.90 μg/mL and were adequate for the specific application. The developed method was successfully applied to the analysis of the studied drugs in in-vitro drug release samples obtained from 3D-printed tablets combining the above-mentioned active pharmaceutical ingredients (APIs).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2024.116324DOI Listing

Publication Analysis

Top Keywords

method
8
hplc method
8
hydrochlorothiazide diltiazem
8
diltiazem propranolol
8
critical method
8
analytical qbd
4
qbd optimization
4
optimization multimode
4
multimode hplc
4
method investigation
4

Similar Publications