A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of varying cuff sizes with identical inner diameter on endotracheal intubation in critically ill adults: A sealed tracheal controlled trial. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The present study aims to determine the impact of different cuff diameters on the cuff pressure of endotracheal tubes (ETTs) when the trachea is adequately sealed.

Methods: In the present single-center clinical trial, adult patients who underwent cardiothoracic surgery were assigned to use ETTs from 2 brands (GME and GZW). The primary endpoint comprised of the following: cuff diameter, inner diameter of the ETT, manufacturer, and the number of subjects with tracheal leakage when the cuff pressure was 30 cm H2O.

Results: A total of 298 patients were assigned into 2 groups, based on the 2 distinct brands of ETTs: experimental group (n = 122, GME brand) and control group (n = 176, GZW brand). There were no significant differences in baseline characteristics. However, the cuff diameter was significantly smaller in the control group, when compared to the experimental group (P = .001), and the incidence of tracheal leakage was significantly higher in the control group (P = .001). Furthermore, the GME brand ETT had a significantly larger cuff diameter, when compared to the GZW brand ETT.

Conclusion: The cuff size would mismatch the tracheal area in clinical practice. Therefore, chest computed tomography is recommended to routinely evaluate the tracheal cross-sectional area during anesthesia, in order to ensure the appropriate cuff size selection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11175911PMC
http://dx.doi.org/10.1097/MD.0000000000038326DOI Listing

Publication Analysis

Top Keywords

cuff diameter
12
control group
12
inner diameter
8
cuff
8
cuff pressure
8
tracheal leakage
8
experimental group
8
gme brand
8
gzw brand
8
group p = 001
8

Similar Publications