Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a nonthermal ablation modality, was noninferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects.
Objectives: This study sought to compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA vs thermal ablation.
Methods: ADVENT (FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation) was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead electrocardiogram, whereas follow-up HRs, as well as HRV (standard deviation of all normal to normal RR intervals, standard deviation of 5-minute average RR intervals) metrics, were derived from 72-hour Holter monitors at 6 and 12 months.
Results: This study included 379 paroxysmal AF patients undergoing PFA (n = 194) or thermal ablation (n = 185; n = 102 RF, n = 83 CB) completing 6- and 12-month Holter monitoring. Compared with PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs 5.9 beats/min; P = 0.02) and 12 months (ΔHR; 8.8 vs 5.2 beats/min; P = 0.03). This increase in HR at 6 and 12 months was similar between CB and RF (P = 0.94 and 0.83, respectively). HRV, both standard deviation of all normal to normal RR intervals and standard deviation of 5-minute average RR intervals, were significantly lower at both 6 and 12 months after thermal ablation compared with PFA (P < 0.01).
Conclusions: PFA's effect on the autonomic nervous system was attenuated compared with thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacep.2024.05.005 | DOI Listing |