A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A pin-based probe for electronic moisture meters to determine moisture content in a single wheat kernel. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Optimum moisture in straw and grain at maturity is important for timely harvesting of wheat. Grain harvested at the right time has reduced chance of being affected by adverse weather conditions which is important to maintain grain quality and end use functionality. Wheat varieties with a short dry down period could help in timely harvest of the crop. However, measuring single kernel moisture in wheat and other small grain crops is a phenotyping bottleneck which requires characterising moisture content of the developing kernel at physiological maturity.

Results: Here we report developing a pin-based probe to detect moisture in a developing wheat kernel required for determining physiological maturity. An in-house designed pin-based probe was used with different commercially available electronic moisture meters to assess the moisture content of the individual kernels in spikes with high accuracy (R = 0.73 to 0.94, P < 0.001) compared with a reference method of oven drying. The average moisture values varied among different electronic moisture meters and the oven-dry method and differences in values were minimized at low kernel moisture content (< 50%). The single kernel moisture probe was evaluated in the field to predict the physiological maturity in wheat using 38% moisture content as the reference and visible notes on kernel stage.

Conclusion: The pin-based moisture probe is a reliable tool for wheat physiologists and breeders to conveniently and accurately measure moisture content in developing grain that will aid in identifying wheat germplasm with fast dry-down characteristics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11163790PMC
http://dx.doi.org/10.1186/s13007-024-01194-3DOI Listing

Publication Analysis

Top Keywords

pin-based probe
12
moisture content
12
moisture
8
electronic moisture
8
moisture meters
8
wheat kernel
8
wheat
5
probe electronic
4
meters determine
4
determine moisture
4

Similar Publications