A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

POF-based biosensors for cortisol detection in seawater as a tool for aquaculture systems. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A surface plasmon resonance (SPR) phenomenon implemented via D-shaped polymer optical fiber (POF) is exploited to realize cortisol biosensors. In this work, two immonosensors are designed and developed for the qualitative as well as quantitative measurement of cortisol in artificial and real samples. The performances of the POF-based biosensors in cortisol recognition are achieved using different functionalization protocols to make the same antibody receptor layer over the SPR surface via cysteamine and lipoic acid, achieving a limit of detection (LOD) of 0.8 pg/mL and 0.2 pg/mL, respectively. More specifically, the use of cysteamine or lipoic acid changes the distance between the receptor layer and the SPR surface, improving the sensitivity at low concentrations of about one order of magnitude in the configuration based on lipoic acid. The LODs of both cortisol biosensors are achieved well competitively with other sensor systems but without the need for amplification or sample treatments. In order to obtain the selectivity tests, cholesterol and testosterone were used as interfering substances. Moreover, tests in simulated seawater were performed for the same cortisol concentration range achieved in buffer solution to assess the immunosensor response to the complex matrix. Finally, the developed cortisol biosensor was used in a real seawater sample to estimate the cortisol concentration value. The gold standard method has confirmed the estimated cortisol concentration value in real seawater samples. Liquid-liquid extraction was implemented to maximize the response of cortisol in liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11161578PMC
http://dx.doi.org/10.1038/s41598-024-63870-7DOI Listing

Publication Analysis

Top Keywords

lipoic acid
12
cortisol concentration
12
cortisol
10
pof-based biosensors
8
biosensors cortisol
8
cortisol biosensors
8
receptor layer
8
layer spr
8
spr surface
8
cysteamine lipoic
8

Similar Publications