A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Quantitative determination of nitrous oxide in human blood by HS-GC-MS: forensic application of two fatal poisoning cases. | LitMetric

Quantitative determination of nitrous oxide in human blood by HS-GC-MS: forensic application of two fatal poisoning cases.

Forensic Sci Int

Department of Forensic Toxicology, Academy of Forensic Science, Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Science Platform, Key Laboratory of Forensic Sciences, Ministry of Justice, Shanghai 200063, PR China. Electronic address:

Published: July 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Nitrous oxide (NO), also known as laughing gas, has a euphoric effect and is becoming increasingly popular as a recreational inhalant drug. Deaths caused by recreational nitrous oxide abuse are rare, but may still occur. Although some methods for the quantification of NO by GC-MS have been reported, elimination of carbon dioxide interference and the choice of a suitable internal standard remain current limitations to accurate NO quantification. Here, a validated method using headspace-gas chromatography-mass spectrometry (HS-GC-MS) is described that allows the quantification of NO in human blood samples: sodium hydroxide is used to remove carbon dioxide, and n-pentane is chosen as a suitable internal standard. Collectively, the validation results show a good linear relationship of NO in blood within the concentration range of 0.02 ∼ 0.5 mL/mL and an LOD of 0.005 mL/mL. Subsequent application of the validated method to two real mortality cases due to NO intoxication provided reference values for blood concentrations in forensic cases. Other biological specimens (gaseous samples and tissues) of the deceased were also analyzed to demonstrate that the deaths were caused by asphyxia due to the inhalation of NO.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.forsciint.2024.112067DOI Listing

Publication Analysis

Top Keywords

nitrous oxide
12
human blood
8
deaths caused
8
carbon dioxide
8
suitable internal
8
internal standard
8
validated method
8
quantitative determination
4
determination nitrous
4
oxide human
4

Similar Publications