98%
921
2 minutes
20
Cardiac output (CO) is one of the primary prognostic factors evaluated during the follow-up of patients treated for pulmonary hypertension (PH). It is recommended that it be measured using the thermodilution technique during right heart catheterization. The difficulty to perform iterative invasive measurements on the same individual led us to consider a non-invasive option. The aims of the present study were to assess the agreement between CO values obtained using bioreactance (Starling™ SV) and thermodilution, and to evaluate the ability of the bioreactance monitor to detect patients whose CO decreased by more than 15% during follow-up and, accordingly, its usefulness for patient monitoring. A prospective cohort study evaluating the performance of the Starling™ SV monitor was conducted in patients with clinically stable PH. Sixty patients referred for hemodynamic assessment were included. CO was measured using both the thermodilution technique and bioreactance during two follow-up visits. A total of 60 PH patients were included. All datasets were available at the baseline visit (V0) and 50 of them were usable during the follow-up visit (V1). Median [IQR] CO was 4.20 l/min [3.60-4.70] when assessed by bioreactance, and 5.30 l/min [4.57-6.20] by thermodilution (p<0.001). The Spearman correlation coefficient was 0.51 [0.36-0.64], and the average deviation on Bland-Altman plot was -1.25 l/min (95% CI [-1.48-1.01], p<0.001). The ability of the monitor to detect a variation in CO of more than 15% between two follow-up measurements, when such variation existed using thermodilution, was insufficient for clinical practice (AUC = 0.54, 95% CI [0.33-0.75]).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11104646 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0298727 | PLOS |
Aims: Many patients develop Fontan-associated liver disease (FALD) after undergoing the Fontan procedure-a surgical treatment for congenital heart disease such as single ventricle-owing to changes in venous pressure and cardiac output. Liver biopsy is the gold standard for diagnosing FALD, but has limitations. Magnetic resonance elastography (MRE) is a popular non-invasive method for evaluating liver stiffness and fibrosis in FALD; however, no unified view exists.
View Article and Find Full Text PDFCureus
August 2025
Neuroanesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, IND.
Introduction: Maintaining hemodynamic stability during the perioperative period of major neurosurgical procedures is of paramount importance. A major challenge for anesthesiologists during hemodynamic fluctuations is identifying the underlying cause to guide appropriate therapy. Limited literature is available on the utility of transesophageal echocardiography (TEE) during hemodynamic fluctuations in major neurosurgery.
View Article and Find Full Text PDFJ Am Soc Echocardiogr
September 2025
From the Department of Cardiovascular Medicine, Mayo Clinic Rochester, MN 55905.
Background: Pulmonary hypertension is associated with cardiovascular events, but when assessed at rest, it has limited sensitivity. Pulmonary vascular reserve can be assessed noninvasively using exercise echocardiography, but this has not been studied in adults with coarctation of aorta (COA). We hypothesized that adults with COA had worse pulmonary vascular reserve compared to controls, and that impaired pulmonary vascular reserve was associated with clinical indices of disease severity independent right ventricular (RV) indices at rest.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
September 2025
Texas Cardiac Arrhythmia Institute, St. David's Medical Center, 3000 N Interstate 35, Suite 700, Austin, TX, 78705, USA.
Background: Dedicated radiofrequency (RF) needles and wires for transseptal puncture (TSP) achieve better outcomes vs. electrified open-ended needles and guidewires due to optimized electrode design and energy delivery. This study benchmarked TSP performance between the dedicated VersaCross wire system (VC; Boston Scientific) and an electrified guidewire with an alternative electrode configuration similar to commercially available devices.
View Article and Find Full Text PDFOpen Heart
September 2025
Cardiology Department, Sahlgrenska University Hospital, Gothenburg, Sweden.
Aims: We investigated the prevalence of coronary microvascular dysfunction (CMD) and its association with severity of heart failure in patients with reduced or mildly reduced ejection fraction (HFrEF and HFmrEF).
Method: Patients with stable, symptomatic heart failure with left ventricular ejection fraction (LVEF) <50% were enrolled. Data collection included physical examination, blood samples, Kansas City Cardiomyopathy Questionnaire (KCCQ), carotid to femoral pulse wave velocity, echocardiography and adenosine-based transthoracic Doppler echocardiography to assess coronary flow reserve (CFR).