A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Updated 2022 ACC/AHA Guideline Improves Concordance Between TTE and CT in Monitoring Marfan Snydrome and Related Disorders, but Relevant Measurement Differences Remain Frequent. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Patients diagnosed with Marfan syndrome or a related syndrome require frequent aorta monitoring using imaging techniques like transthoracic echocardiography (TTE) and computed tomography (CT). Accurate aortic measurement is crucial, as even slight enlargement (>2 mm) often necessitates surgical intervention. The 2022 ACC/AHA guideline for Aortic Disease Diagnosis and Management includes updated imaging recommendations. We aimed to compare these with the 2010 guideline.

Methods: This retrospective study involved 137 patients with Marfan syndrome or a related disorder, undergoing TTE and ECG-triggered CT. Aortic diameter measurements were taken based on the old 2010 guideline (TTE: inner edge to inner edge, CT: external diameter) and the new 2022 guideline (TTE: leading edge to leading edge, CT: internal diameter). Bland-Altman plots compared measurement differences.

Results: Using the 2022 guideline significantly reduced differences outside the clinical agreement limit from 49% to 26% for the aortic sinus and from 41% to 29% for the ascending aorta. Mean differences were -0.30 mm for the aortic sinus and +1.12 mm for the ascending aorta using the 2022 guideline, compared to -2.66 mm and +1.21 mm using the 2010 guideline.

Conclusion: This study demonstrates for the first time that the 2022 ACC/AHA guideline improves concordance between ECG-triggered CT and TTE measurements in Marfan syndrome patients, crucial for preventing life-threatening aortic complications. However, the frequency of differences >2 mm remains high.

Clinical Relevance/application: Accurate aortic diameter measurement is vital for patients at risk of fatal aortic complications. While the 2022 guideline enhances concordance between imaging modalities, frequent differences >2 mm persist, potentially impacting decisions on aortic repair. The risk of repeat radiation exposure from ECG-triggered CT, considered the 'gold standard', continues to be justified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11086607PMC
http://dx.doi.org/10.5334/gh.1322DOI Listing

Publication Analysis

Top Keywords

2022 guideline
16
2022 acc/aha
12
acc/aha guideline
12
marfan syndrome
12
aortic
9
guideline
8
guideline improves
8
improves concordance
8
accurate aortic
8
aortic diameter
8

Similar Publications