Introduction: Endoleaks represent one of the main complications after endovascular aortic repair (EVAR) and can lead to increased re-intervention rates and secondary rupture. Serial lifelong surveillance is required and traditionally involves cross-sectional imaging with manual axial measurements. Artificial intelligence (AI)-based imaging analysis has been developed and may provide a more precise and faster assessment. This study aims to evaluate the ability of an AI-based software to assess post-EVAR morphological changes over time, detect endoleaks, and associate them with EVAR-related adverse events.

Methods: Patients who underwent EVAR at a tertiary hospital from January 2017 to March 2020 with at least 2 follow-up computed tomography angiography (CTA) were analyzed using PRAEVAorta 2 (Nurea). The software was compared to the ground truth provided by human experts using Sensitivity (Se), Specificity (Sp), Negative Predictive Value (NPV), and Positive Predictive Value (PPV). Endovascular aortic repair-related adverse events were defined as aneurysm-related death, rupture, endoleak, limb occlusion, and EVAR-related re-interventions.

Results: Fifty-six patients were included with a median imaging follow-up of 27 months (interquartile range [IQR]: 20-40). There were no significant differences overtime in the evolution of maximum aneurysm diameters (55.62 mm [IQR: 52.33-59.25] vs 54.34 mm [IQR: 46.13-59.47]; p=0.2162) or volumes (130.4 cm [IQR: 113.8-171.7] vs 125.4 cm [IQR: 96.3-169.1]; p=0.1131) despite a -13.47% decrease in the volume of thrombus (p=0.0216). PRAEVAorta achieved a Se of 89.47% (95% confidence interval [CI]: 80.58 to 94.57), a Sp of 91.25% (95% CI: 83.02 to 95.70), a PPV of 90.67% (95% CI: 81.97 to 95.41), and an NPV of 90.12% (95% CI: 81.70 to 94.91) in detecting endoleaks. Endovascular aortic repair-related adverse events were associated with global volume modifications with an area under the curve (AUC) of 0.7806 vs 0.7277 for maximum diameter. The same trend was observed for endoleaks (AUC of 0.7086 vs 0.6711).

Conclusions: The AI-based software PRAEVAorta enabled a detailed anatomic characterization of aortic remodeling post-EVAR and showed its potential interest for automatic detection of endoleaks during follow-up. The association of aortic aneurysmal volume with EVAR-related adverse events and endoleaks was more robust compared with maximum diameter.

Clinical Impact: The integration of PRAEVAorta AI software into clinical practice promises a transformative shift in post-EVAR surveillance. By offering precise and rapid detection of endoleaks and comprehensive anatomic assessments, clinicians can expect enhanced diagnostic accuracy and streamlined patient management. This innovation reduces reliance on manual measurements, potentially reducing interpretation errors and shortening evaluation times. Ultimately, PRAEVAorta's capabilities hold the potential to optimize patient care, leading to more timely interventions and improved outcomes in endovascular aortic repair.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15266028241252097DOI Listing

Publication Analysis

Top Keywords

endovascular aortic
20
aortic repair
12
adverse events
12
artificial intelligence
8
ai-based software
8
evar-related adverse
8
aortic repair-related
8
repair-related adverse
8
detection endoleaks
8
aortic
7

Similar Publications

Background: There is conflicting literature regarding mortality outcomes associated with REBOA usage in patients with severe thoracic or abdominal trauma. Our study aims to assess the benefits and negative implications of REBOA use in adult trauma patients in hemorrhagic shock with severe thoracic or abdominal injuries.

Methods: This retrospective cohort analysis utilized the American College of Surgeons Trauma Quality Improvement Program Participant Use File (ACS-TQIP-PUF) database from 2017 to 2023 to evaluate adult patients with severe isolated thoracic or abdominal trauma undergoing REBOA placement.

View Article and Find Full Text PDF

Transposing intensive care innovation from modern warfare to other resource-limited settings.

Eur J Trauma Emerg Surg

September 2025

French Military Medical Service Academy - École du Val-de-Grâce, Paris, France.

Background: Delivering intensive care in conflict zones and other resource-limited settings presents unique clinical, logistical, and ethical challenges. These contexts, characterized by disrupted infrastructure, limited personnel, and prolonged field care, require adapted strategies to ensure critical care delivery under resource-limited settings.

Objective: This scoping review aims to identify and characterize medical innovations developed or implemented in recent conflicts that may be relevant and transposable to intensive care units operating in other resource-limited settings.

View Article and Find Full Text PDF

Introduction: The aim of this article is to compare the long-term efficacy of Thoracic Endovascular Aortic Repair (TEVAR) versus Optimal Medical Therapy (OMT) in reducing mortality among adult patients with uncomplicated Stanford type B aortic dissection (uSTBAD).

Methods: An electronic search of PubMed, Cochrane Central and Google Scholar was conducted for studies comparing TEVAR with OMT for mortality in adult patients with uSTBAD. Relevant outcomes, including mortality, aortic rupture, re-intervention, retrograde type A dissection, myocardial infarction and stroke were analyzed and presented as risk ratios (RRs) along with their 95% confidence intervals (95% CI).

View Article and Find Full Text PDF