Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: Patient-reported outcomes (PROs) provide important insights into patients' acceptance of their medical devices. Avoid Transvenous Leads in Appropriate Subjects (ATLAS), a randomized, multi-centre, open-label clinical trial, recently reported fewer perioperative complications in subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous ICD (TV-ICD) patients. This study reports PROs, including device-specific and generic quality of life (QOL), from the ATLAS trial.

Methods And Results: Device-specific QOL was the primary PRO using the Florida Patient Acceptance Survey (FPAS) at 1 and 6 months' post-implantation. Secondary outcomes included generic QOL using the Medical Outcomes Survey (SF-36) pre-implant and 6 months' post-implantation. The FPAS and SF-36 were analysed using analysis of covariance. Pain measured using a Numeric Rating Scale, at 1 and 6 months, anaesthetic, body mass index, and within/between differences were analysed using descriptive statistics and mixed-effects linear models. Of the 503 patients randomized in ATLAS, 404 had complete FPAS data to be included in this analysis. Participant characteristics were balanced. There were no significant differences between S-ICD and TV-ICD for the FPAS or SF-36, across time points. Mean total FPAS scores increased from 73.73 (16.09) to 77.05 (16.13) and 74.43 (15.35) to 78.25 (15.88) for S-ICD and TV-ICD, respectively (P < 0.001). Patient-reported outcomes suggested that both devices were associated with good QOL.

Conclusion: Device-specific and generic QOL were similar between S-ICD and TV-ICD groups up to 6 months' post-implantation, indicating that regardless of device type, both groups reported good device-specific QOL in ATLAS patients. Subcutaneous ICD patients reported higher pain scores at implant, but pain decreased by 6 months. The findings offer evidence that can be included during shared decision-making. The inclusion of patient partners in ATLAS provided an opportunity to measure PROs that were deemed important to patients.

Registration: ClinialTrials.gov: NCT02881255.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurjcn/zvae067DOI Listing

Publication Analysis

Top Keywords

months' post-implantation
12
s-icd tv-icd
12
quality life
8
transvenous leads
8
leads appropriate
8
appropriate subjects
8
patient-reported outcomes
8
device-specific generic
8
qol atlas
8
device-specific qol
8

Similar Publications

Application of high-resolution cone-beam computed tomography for evaluation of endothelialization after flow diverter implantation for unruptured intracranial aneurysms.

AJNR Am J Neuroradiol

September 2025

From the Department of Interventional Radiology (Shuailong Shi, Shuhai Long, Ji Ma, Peijie Lu, Jie Yang, Ye Wang, Tengfei Li), The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China; The School of Life Science and Technology (Zhike Zhang), Xi'an Jiaotong University, Xi'an, China; an

Background And Purpose: Although high-resolution cone-beam computed tomography (HR-CBCT) is used for immediate evaluation of stent apposition, studies using this technique to evaluate flow diverter (FD) endothelialization during follow-up are limited. The study aims to investigate the potential of HR-CBCT in assessing FD endothelialization and identify factors influencing poor endothelialization.

Materials And Methods: The clinical and imaging data of patients with unruptured intracranial aneurysms (UIAs) treated by FDs from March 2019 to October 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Purpose: The analgesic mechanisms and neurophysiological effects of spinal cord stimulation (SCS) and dorsal root ganglion stimulation (DRGS) are poorly understood. In this pilot repeated-measures study, we used quantitative sensory testing (QST) and self-reported questionnaires to investigate the effects of these therapies in chronic pain patients from pre-implantation up to one-year post-implantation. Several studies have reported stimulation-induced effects on QST, potentially clarifying how neurostimulation affects the nervous system, which is poorly understood.

View Article and Find Full Text PDF

Background: Cardiac resynchronization therapy (CRT) has been established as a key component in the management of patients with heart failure (HF) with reduced ejection fraction in addition to pharmacologic therapy. Several automatic algorithms have been developed to optimize the timing cycle settings in CRT, especially AV delay which was associated with improvement of the response to CRT. The present study aims to investigate whether the novel device-based SyncAV algorithm could elicit better synchrony and acute hemodynamic response.

View Article and Find Full Text PDF

This study characterized collagen remodeling in an electron-beam-sterilized porcine acellular dermal matrix (E-PADM) by evaluating host response kinetics during wound healing. E-PADM ( = 6 lots/time point) was implanted in an abdominal wall bridging defect in nonhuman primates ( = 24). Histological, immunohistochemical, and biochemical assessments were conducted.

View Article and Find Full Text PDF

Tracheal collapse (TC), defined by excessive tracheal collapsibility, often results in severe respiratory distress in small-breed dogs. Surgical intervention, including the placement of extraluminal stents, has been employed as a treatment option. Owing to the anatomical and physiological similarities between rabbit and canine tracheas, a rabbit model was utilized to develop a novel extraluminal silicone tracheal stent and evaluate its feasibility in treating tracheomalacia.

View Article and Find Full Text PDF