Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study introduces a straightforward method for depositing InZnSnO films onto flexible polyimide substrates at room temperature, enabling their application in electrochemical pH sensing and the detection of epinephrine. A comprehensive analysis of these sensing films, spanning structural, morphological, compositional, and profiling characteristics, was conducted using diverse techniques, including X-ray diffraction, atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectroscopy. The investigation into the influence of oxygen flow rates on the performance of InZnSnO sensitive films revealed a significant correlation between their structural properties and sensing capabilities. Notably, exposure to an oxygen flow rate of 30/2 (Ar/O) the ratio of resulted in the InZnSnO sensitive film demonstrating outstanding pH sensitivity at 59.58 mV/pH within a broad pH range of 2-12, surpassing the performance observed with other oxygen flow rates. Moreover, under this specific condition, the film exhibited excellent stability, with a minimal drift rate of 0.14 mV/h at pH 7 and a low hysteresis voltage of 1.8 mV during a pH cycle of 7 → 4→7 → 10→7. Given the critical role of epinephrine in mammalian central nervous and hormone systems, monitoring its levels is essential for assessing human health. To facilitate the detection of epinephrine, we utilized the carboxyl group of 4-formylphenylboronic acid to enable a reaction with the amino group of the 3-aminopropyltriethoxysilane-coated InZnSnO film. Through optimization, the resulting InZnSnO-based flexible sensor displayed a broad and well-defined linear relationship within the concentration range of 10 to 0.1 μM. In practical applications, this sensor proved effective in analyzing epinephrine in human serum, showcasing notable selectivity, stability, and reproducibility. The promising outcomes of this study underscore the potential for future applications, leveraging the advantages of electrochemical sensors, including affordability, rapid response, and user-friendly operation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.126178DOI Listing

Publication Analysis

Top Keywords

oxygen flow
12
flexible sensor
8
sensing films
8
detection epinephrine
8
flow rates
8
inznsno sensitive
8
epinephrine
5
inznsno
5
simple highly
4
highly sensitive
4

Similar Publications

Background: Triple-negative breast cancer (TNBC) carries a substantial risk of recurrence and metastasis, posing significant threats to patients' health and quality of life. Centrosomal protein 55 (CEP55) has been demonstrated to exhibit elevated expression levels in TNBC. However, its molecular regulatory mechanism in TNBC remains unclear.

View Article and Find Full Text PDF

Knockdown of LOXL2 suppresses cuproptosis induced by HO to inhibited the procession of ulcerative colitis.

Int Immunopharmacol

September 2025

The Second Department of Gastroenterology, Shengjing Hospital of China Medical University, No. 36, Sanhao Road, Heping District, Shenyang 110000, Liaoning, China. Electronic address:

Purpose: This study aimed to elaborate the mechanism of cuproptosis induced by HO in ulcerative colitis (UC).

Methods: Bioinformatics based on GSE107499, GSE87466, and GSE92415 datasets was performed to screen hub genes related to cuproptosis. In vitro, cell counting kit 8 (CCK8), flow cytometry were applied for detecting cell proliferation and apoptosis.

View Article and Find Full Text PDF

Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.

View Article and Find Full Text PDF

Titanium dioxide (TiO) thin films were deposited on glass substrates under HV conditions at room temperature by the physical vapor deposition method. Produced titanium thin films were post-annealed at 573 K at different oxygen flows (0, 9 and 23 cm/s). The influence of different oxygen flows on nano-structure, crystallography, and optical parameters of TiO films was investigated by XRD, AFM, and spectrophotometer in the UV-VIS wavelength range.

View Article and Find Full Text PDF

Purpose: There is limited evidence to guide the use of enteral nutrition (EN) for children with bronchiolitis who received Humidified high flow nasal cannula (HHFNC) and often kept nil per mouth for aspiration and progression to mechanical ventilation risk.

Methods: This quality improvement project included children with bronchiolitis who were supported by HHFNC in the paediatric intensive care unit (PICU). An algorithm to increase EN use in those participants was created by stakeholders.

View Article and Find Full Text PDF