Inappropriate Peak Inspiratory Flow Rate in the Patients with Stable Chronic Obstructive Pulmonary Disease in Korea.

Tuberc Respir Dis (Seoul)

Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Republic of Korea.

Published: October 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: While inhalation therapy efficacy hinges on attaining proper peak inspiratory flow rate (PIFR), the prevalence of inappropriate PIFR among patients with chronic obstructive pulmonary disease (COPD) remains unstudied in Korea. This study aimed to assess the prevalence of inappropriate PIFR, its correlation with COPD assessment test (CAT) scores, and factors associated with suboptimal PIFR.

Methods: We enrolled 108 patients with COPD who had been using the same inhaler for at least 1 year without exacerbations. PIFR was measured using an inspiratory flow meter (In-Check DIAL G16). Demographic, clinical, pulmonary function, and CAT score data were collected. Inappropriate was defined as PIFR <60 L/min for dry power inhaler (DPI) users, and >90 L/min for aerosol device users.

Results: The cohort comprised 87 (80.6%) men, mean age 71.0±8.5 years, with mean post-bronchodilator forced expiratory volume in 1 second of 69.1%±1.8% predicted. Twenty-nine (26.9%) used aerosol devices only, 76 (70.4%) used DPIs only, and three (2.8%) used both. Inappropriate PIFRs were found in 17.2% of aerosol device users, and 42.1% of DPI users. CAT scores were significantly higher in the inappropriate PIFR group than in the appropriate PIFR group (11.2±7.7 vs. 7.5±4.9, p=0.003). In DPI users, female, shorter height, lower body weight and maximal voluntary ventilation (MVV) were associated with inappropriate PIFR.

Conclusion: The prevalence of inappropriate PIFR among patients with COPD is 17.2% for aerosol device users, and 42.1% for DPI users. Suboptimal PIFR correlates with female gender, shorter stature, lower weight and MVV in DPI users.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11468443PMC
http://dx.doi.org/10.4046/trd.2023.0195DOI Listing

Publication Analysis

Top Keywords

dpi users
20
inappropriate pifr
16
inspiratory flow
12
prevalence inappropriate
12
aerosol device
12
pifr
9
inappropriate
8
peak inspiratory
8
flow rate
8
chronic obstructive
8

Similar Publications

Objective risk assessment of bark and ambrosia beetles non-indigenous to North America.

Ecol Appl

July 2025

School of Forest, Fisheries and Geomatics Sciences, University of Florida, Gainesville, Florida, USA.

Pest risk assessment informs regulatory decisions to facilitate safe trade while also protecting a country's agricultural and environmental resources. The first step in pest risk assessment is pest categorization which can help determine whether an in-depth examination is needed. We created a model to predict the potential impact of non-indigenous bark and ambrosia beetles (Curculionidae: Scolytinae).

View Article and Find Full Text PDF

Efficacy of Inhaler Devices in New-Onset Mild Asthma: A Randomized Blinded Multicenter Trial.

Adv Ther

August 2025

Department of Respiratory and Critical Care Medicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, No. 100 Haining Rd, Shanghai, 200080, China.

Introduction: Low-dose inhaled corticosteroids (ICS) manage mild bronchial asthma effectively. Although pressurized metered-dose inhalers (pMDI) and dry powder inhalers (DPI) demonstrate similar efficacy in moderate-to-severe asthma, their effectiveness against mild asthma remains less established. This multicenter study evaluates the efficacy of ICS-pMDI versus ICS-DPI in newly diagnosed mild asthma.

View Article and Find Full Text PDF

Background: Dry powder inhalers (DPIs) are commonly used among patients with Chronic Obstructive Pulmonary Disease (COPD). These inhalers are breath-actuated, and require patients to generate sufficient peak inspiratory flow (PIF) to disaggregate the drug powder into respirable fine particles and deliver it to the lower airway tracts. Inhaler personalisation based on PIF among DPI users has not been studied in Malaysia, thus we conducted the present pilot study to determine the feasibility of conducting such research among COPD patients.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the prevalence of oral candidiasis (OC) among patients with asthma and COPD undergoing inhaled corticosteroid (ICS) therapy at the Philippine General Hospital from October 2019 to January 2020.
  • Results showed that 5.97% of ICS users had OC, with a prevalence range of 1.65% to 14.59%, but the small sample size limited definitive conclusions.
  • The findings indicate some associations, like higher OC prevalence in adult females on low dose Fluticasone/Salmeterol DPI for over a year, and suggest that larger studies are needed to explore the relationship between OC and ICS therapy factors more thoroughly.
View Article and Find Full Text PDF

Comparisons between In-Check DIAL® and PF810® in evaluation and training inspiratory capacity for using dry powder inhalers.

BMC Pulm Med

August 2024

Department of Pulmonary and Critical Care Medicine, Zhongshan Hospital, Shanghai Medical College, Fudan University, Shanghai, China.

Background: Dry powder inhalers (DPIs) rely on both internal resistance and patients' inspiratory capacity for effective operation. Optimal inspiratory technique is crucial for DPI users. This study assessed the accuracy and repeatability of two available devices, PF810® and In-Check DIAL®, and analyzed their measurement errors and consistency in detecting inspiratory capacity.

View Article and Find Full Text PDF