Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
To enhance M-mode echocardiography's utility for measuring cardiac structures, we developed and evaluated an artificial intelligence (AI)-based automated analysis system for M-mode images through the aorta and left atrium [M-mode (Ao-LA)], and through the left ventricle [M-mode (LV)]. Our system, integrating two deep neural networks (DNN) for view classification and image segmentation, alongside an auto-measurement algorithm, was developed using 5,958 M-mode images [3,258 M-mode (LA-Ao), and 2,700 M-mode (LV)] drawn from a nationwide echocardiographic dataset collated from five tertiary hospitals. The performance of view classification and segmentation DNNs were evaluated on 594 M-mode images, while automatic measurement accuracy was tested on separate internal test set with 100 M-mode images as well as external test set with 280 images (140 sinus rhythm and 140 atrial fibrillation). Performance evaluation showed the view classification DNN's overall accuracy of 99.8% and segmentation DNN's Dice similarity coefficient of 94.3%. Within the internal test set, all automated measurements, including LA, Ao, and LV wall and cavity, resonated strongly with expert evaluations, exhibiting Pearson's correlation coefficients (PCCs) of 0.81-0.99. This performance persisted in the external test set for both sinus rhythm (PCC, 0.84-0.98) and atrial fibrillation (PCC, 0.70-0.97). Notably, automatic measurements, consistently offering multi-cardiac cycle readings, showcased a stronger correlation with the averaged multi-cycle manual measurements than with those of a single representative cycle. Our AI-based system for automatic M-mode echocardiographic analysis demonstrated excellent accuracy, reproducibility, and speed. This automated approach has the potential to improve efficiency and reduce variability in clinical practice.