Article Abstract

Background: Sexual minority men (SMM) with HIV who use stimulants may experience greater difficulties with antiretroviral therapy adherence which amplifies risk for unsuppressed HIV viral load (VL). Remote monitoring of VL could support efforts to rapidly respond to sub-optimal adherence.

Methods: This qualitative study enrolled 24 SMM with HIV who use stimulants to examine experiences with two different dried blood spots (DBS) self-sampling devices (i.e., Tasso-M20 vs. HemaSpot HD) to measure VL. Participants were asked to complete self-sampling of DBS using both devices, and then participated in a 45-minute semi-structured interview. Interviews focused on ease of use, device preference, experiences with receiving and mailing kits, and barriers to participating in research. A thematic analysis was conducted to analyze interviews transcripts.

Results: Twenty-two participants (92%) returned the Tasso-M20 and 21 (88%) returned the Hemaspot HD devices. Among the 22 participants that completed qualitative interviews, twenty-three codes were identified and collapsed within seven themes. Preferences for devices were based on convenience, pain and prior experiences with finger-pricking technology. Participants emphasized that clearer instructions with contingency plans for self-sampling of DBS would improve the user experience with self-sampling of DBS. Intersectional stigma (e.g., HIV, sexual minority status, and substance use) was noted as an important consideration in implementing self-sampling of DBS. Promoting decision making, or the option to choose sampling method based on personal preferences, may improve engagement and likelihood of DBS completion.

Conclusions: Findings will guide the broader implementation of self-sampling of DBS to optimize VL monitoring in SMM with HIV who use stimulants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11030538PMC
http://dx.doi.org/10.21203/rs.3.rs-4132978/v1DOI Listing

Publication Analysis

Top Keywords

self-sampling dbs
20
smm hiv
12
hiv stimulants
12
implementing self-sampling
8
dried blood
8
blood spots
8
hiv viral
8
viral load
8
sexual minority
8
self-sampling
7

Similar Publications

Comparison of capillary dried blood spot and capillary microtubes with venous immunoglobulin G levels for routine diagnostics.

Clin Biochem

August 2025

Department of Central Diagnostic Laboratory, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands. Electronic address:

Background And Aims: Patients with primary antibody deficiencies receiving immunoglobulin replacement therapy require frequent monitoring of immunoglobulin G (IgG) levels. Capillary IgG measurements from dried blood spots (DBS) or microtubes offer several advantages over samples obtained by venipuncture, including facilitating remote self-sampling. However, the validity of this alternative method is still unknown.

View Article and Find Full Text PDF

Microsampling, using minute amounts of biological specimen, is uniquely suited for carrying out human and animal pharmacokinetic and toxicokinetic studies. Indeed, it provides important advantages over common blood-drawing procedures (e.g.

View Article and Find Full Text PDF

'I was like, this is gonna hurt': Implementing self-sampling of dried blood spots to measure HIV viral load.

PLoS One

May 2025

Department of Health Promotion and Disease Prevention, Robert Stempel College of Public Health & Social Work, Florida International University, Miami, Florida, United States of America.

Background: Sexual minority men (SMM) with HIV who use stimulants may experience greater difficulties with antiretroviral therapy adherence which amplifies risk for unsuppressed HIV viral load (VL). Remote monitoring of VL could support efforts to rapidly respond to sub-optimal adherence.

Methods: This qualitative study enrolled 24 SMM with HIV who use stimulants to examine experiences with two different dried blood spots (DBS) self-sampling devices (i.

View Article and Find Full Text PDF

Microsampling techniques and patient-centric therapeutic drug monitoring of immunosuppressants.

Bioanalysis

March 2025

Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Faculty of Pharmacy, Medical University of Warsaw, Warsaw, Poland.

Immunosuppressive pharmacotherapy after solid organ transplantation (SOT) requires therapeutic drug monitoring (TDM) for therapy individualization. The venous whole blood is still considered as routine matrix for monitoring immunosuppressive drug concentration. On the other hand, as an alternative, capillary blood collected using noninvasive sampling is convergent with a patient-centric approach.

View Article and Find Full Text PDF

Therapeutic drug monitoring of levetiracetam - Is dried blood spot sampling suitable?

Clin Biochem

June 2025

Department of Clinical Pharmacology, Therapeutic Drug Monitoring Laboratory, C2-69, Karolinska University Hospital, Stockholm 141 86, Sweden; Department of Laboratory Medicine, Division of Clinical Pharmacology, Karolinska Institute, Stockholm, Sweden.

Background: Therapeutic drug monitoring helps prevent seizures and minimize side effects in epilepsy patients. Phlebotomy is the gold standard for blood collection but can be difficult for children, pregnant women, and patients in remote areas. We previously validated dried blood spot (DBS) sampling for carbamazepine, lamotrigine, levetiracetam (LEV), and valproic acid.

View Article and Find Full Text PDF