Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Unlabelled: The mpox outbreak, caused by monkeypox virus (MPXV), accelerated the development of molecular diagnostics. In this study, we detail the evaluation of the Research Use Only (RUO) NeuMoDx MPXV assay by multiple European and US sites. The assay was designed and developed by Qiagen for the NeuMoDx Molecular Systems. Primers and probes were tested for specificity and inclusivity . The analytical sensitivity of the assay was determined by testing dilutions of synthetic and genomic MPXV DNA. A total of 296 clinical samples were tested by three sites; the Johns Hopkins University (US), UZ Gent (Belgium, Europe), and Hospital Universitario San Cecilio (Spain, Europe). The analytical sensitivity of the assay was 50 copies/mL for both clades I and II. The assay showed 100% identity for 80 clade I and 99.98% identity for 5,162 clade II genomes. Clade II primers and probes showed 100% specificity; however, identity of at least one of the two sets of clade I primers and probes with variola, cowpox, camelpox, and vaccinia viruses was noticed. The clinical validation showed sensitivity of 99.21% [95% confidence interval (CI): 95.66-99.98%] and specificity of 96.64% (95% CI: 91.62-99.08%) for lesion swab samples. The NeuMoDx MPXV Test shows acceptable analytical and clinical performance. The assay improves the laboratory's workflow as it consolidates nucleic acid extraction, PCR, data analysis, and interpretation and can be interfaced. The Test Strip can differentiate clades I and II, which has important laboratory safety implications.
Importance: In this manuscript, we provide detailed analysis and clinical evaluation of the assay using a large cohort of clinical samples across three academic centers in Europe and the United States. Because the assay differentiates MPXV clades I and II, this manuscript is timely due to the current need to rule out the regulated clade I by diagnostic clinical laboratories. In December 2023, and due to first report of cases of sexually transmitted clade I infections in the Democratic Republic of the Congo, when generic assays that do not differentiate the clades are used, samples are considered regulated. The assay meets the need of full automation and has a marked positive impact on the laboratory workflow.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11077944 | PMC |
http://dx.doi.org/10.1128/jcm.00028-24 | DOI Listing |