98%
921
2 minutes
20
This study presents a methodology to prevent the overdesign of electric dispensers for dental impression materials by analyzing the necessary load and determining the appropriate pressurization speed and drive motor capacity. We derived an equation to calculate the required torque and rotational speed of the motor based on the extrusion load and the speed of the impression material. A specialized load measurement system was developed to measure the load necessary to extrude the impression material. Through experiments and image processing, we measured the radius of curvature of the trajectory of the impression material and correlated it with the pressurization speed. Techniques such as position coordinate plotting, curve fitting, and circle fitting were employed to determine the pressurization speed that aligns with the manufacturer's recommended curvature radius. These findings led to a substantial decrease in the necessary motor torque and rotational speed compared with the current standards. This research provides a systematic approach to sizing drive motors using extrusion load and pressurization speed, aiming to reduce overdesign, power consumption, and the weight and size of the motor and battery, thereby contributing to the development of more efficient and compact dental impression material dispensers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11012413 | PMC |
http://dx.doi.org/10.3390/ma17071467 | DOI Listing |
Eur J Dent
September 2025
Clinical Sciences Department, College of Dentistry, Ajman University, Ajman, United Arab Emirates.
The implant impression technique plays a critical role in determining the accuracy of implant working casts. This laboratory study aimed to evaluate and compare the accuracy of working casts fabricated using four different impression techniques in both parallel and nonparallel implant configurations.An aluminum master model was made to simulate a mandibular dental arch.
View Article and Find Full Text PDFJ Prosthodont
September 2025
Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain.
Purpose: The aim of this in vitro study was to assess whether the accuracy (trueness and precision) of full-arch implant digital impressions can be improved by replacing standard digital impressions (StDIs) with segmented digital impressions (SgDIs), obtained by superimposing short-span digital impressions using a geometric pattern.
Materials And Methods: The study was conducted using a commercial edentulous maxillary model with four implants-positioned at the sites of the canines and second molars-and four commercial intraoral scan bodies (ISBs) screwed to them. Ten StDIs and SgDIs of the model were obtained, and their accuracy was evaluated and compared in terms of trueness and precision, based on measurements of three distances and three angles between the ISBs.
Int J Oral Implantol (Berl)
September 2025
Purpose: To present a novel digital workflow (the Columbus Digital Bridge Protocol) for immediately loaded full-arch rehabilitations, integrating digital technologies throughout diagnostic, surgical and prosthetic phases, with a focus on the application of intraoral photogrammetry scanning.
Materials And Methods: The workflow presented in this article, successfully implemented in 14 patients, includes standardised clinical steps: digital diagnostic planning through matching of facial scans and CBCT data, surgical placement of four implants following tooth extraction, immediate post-surgical intraoral photogrammetry scanning using a three-step procedure (i.e.
Auton Agent Multi Agent Syst
September 2025
University of Groningen, Groningen, The Netherlands.
Unlabelled: The popularity of an opinion in one's direct circles is not necessarily a good indicator of its popularity in one's entire community. Network structures make local information about global properties of the group potentially inaccurate, and the way a social network is wired constrains what kind of information distortion can actually occur. In this paper, we discuss which classes of networks allow for a large enough proportion of the population to get a wrong enough impression about the overall distribution of opinions.
View Article and Find Full Text PDFJ Adv Prosthodont
August 2025
Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
Purpose: Designing restorations remains challenging because the process is time-consuming and requires operator skill and experience. This clinical study evaluated the fit accuracy of polymerized complete crowns fabricated using a web-based 3D generative artificial intelligence design (GAID) method compared to crowns fabricated using a conventional computer-aided design (CCAD) method.
Materials And Methods: Sixty-two patients requiring complete crowns in maxillary and mandibular premolars and molars were enrolled.