98%
921
2 minutes
20
Background: We present a case with abnormal findings of initial motor-evoked potential (MEP) in the left upper limb after prone positioning during lumbar spine surgery.
Case Presentation: A 71-year-old man with bilateral lower extremity numbness without a history of preexisting motor weakness underwent L3-5 spinal fenestration. Initial MEP monitoring after prone positioning revealed markedly prolonged latency and lower amplitude in the left abductor pollicis brevis (APB). Because the left upper limb somatosensory-evoked potentials had normal values, a position-related impending peripheral nerve injury located between the neck and the forearm was excluded. Postoperative examination revealed that MEP abnormality in the left APB was caused by carpal tunnel syndrome.
Conclusions: Abnormal initial MEP from the upper limb was unexpectedly detected after prone positioning during lumbar spine surgery. The condition was caused by preexisting carpal tunnel syndrome.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11006633 | PMC |
http://dx.doi.org/10.1186/s40981-024-00708-1 | DOI Listing |
Ophthalmol Glaucoma
September 2025
Department of Ophthalmology and Visual Sciences, University of Michigan W.K. Kellogg Eye Center, Ann Arbor, Michigan. Electronic address:
Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.
Design: Cross-sectional pilot study.
Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.
IEEE Trans Neural Syst Rehabil Eng
September 2025
Force prediction is crucial for functional rehabilitation of the upper limb. Surface electromyography (sEMG) signals play a pivotal role in muscle force studies, but its non-stationarity challenges the reliability of sEMG-driven models. This problem may be alleviated by fusion with electrical impedance myography (EIM), an active sensing technique incorporating tissue morphology information.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
September 2025
Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary noninvasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered.
View Article and Find Full Text PDFBiol Cybern
September 2025
Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, 61801, IL, USA.
In this article, a biophysically realistic model of a soft octopus arm with internal musculature is presented. The modeling is motivated by experimental observations of sensorimotor control where an arm localizes and reaches a target. Major contributions of this article are: (i) development of models to capture the mechanical properties of arm musculature, the electrical properties of the arm peripheral nervous system (PNS), and the coupling of PNS with muscular contractions; (ii) modeling the arm sensory system, including chemosensing and proprioception; and (iii) algorithms for sensorimotor control, which include a novel feedback neural motor control law for mimicking target-oriented arm reaching motions, and a novel consensus algorithm for solving sensing problems such as locating a food source from local chemical sensory information (exogenous) and arm deformation information (endogenous).
View Article and Find Full Text PDFPsychol Res
September 2025
Neurorehabilitation Research Center, Kio University, Nara, Japan.
The ability to detect small errors between sensory prediction in the brain and actual sensory feedback is important in rehabilitation after brain injury, where motor function needs to be restored. To date in the recent study, a delayed visual error detection task during upper limb movement was used to measure this ability for healthy participants or patients. However, this ability during walking, which is the most sought-after in brain-injured patients, was unclear.
View Article and Find Full Text PDF