A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Influence of Body Mass Index on Radiation Exposure Across Imaging Modalities in the Evaluation of Chest Pain. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Essential to a patient-centered approach to imaging individuals with chest pain is knowledge of differences in radiation effective dose across imaging modalities. Body mass index (BMI) is an important and underappreciated predictor of effective dose. This study evaluated the impact of BMI on estimated radiation exposure across imaging modalities.

Methods And Results: This was a retrospective analysis of patients with concern for cardiac ischemia undergoing positron emission tomography (PET)/computed tomography (CT), cadmium zinc telluride single-photon emission CT (SPECT) myocardial perfusion imaging, or coronary CT angiography (CCTA) using state-of-the-art imaging modalities and optimal radiation-sparing protocols. Radiation exposure was calculated across BMI categories based on established cardiac imaging-specific conversion factors. Among 9046 patients (mean±SD age, 64.3±13.1 years; 55% men; mean±SD BMI, 30.6±6.9 kg/m), 4787 were imaged with PET/CT, 3092 were imaged with SPECT/CT, and 1167 were imaged with CCTA. Median (interquartile range) radiation effective doses were 4.4 (3.9-4.9) mSv for PET/CT, 4.9 (4.0-6.3) mSv for SPECT/CT, and 6.9 (4.0-11.2) mSv for CCTA. Patients at a BMI <20 kg/m had similar radiation effective dose with all 3 imaging modalities, whereas those with BMI ≥20 kg/m had the lowest effective dose with PET/CT. Radiation effective dose and variability increased dramatically with CCTA as BMI increased, and was 10 times higher in patients with BMI >45 kg/m compared with <20 kg/m (median, 26.9 versus 2.6 mSv). After multivariable adjustment, PET/CT offered the lowest effective dose, followed by SPECT/CT, and then CCTA (<0.001).

Conclusions: Although median radiation exposure is modest across state-of-the-art PET/CT, SPECT/CT, and CCTA systems using optimal radiation-sparing protocols, there are significant variations across modalities based on BMI. These data are important for making patient-centered decisions for ischemic testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11262536PMC
http://dx.doi.org/10.1161/JAHA.123.033566DOI Listing

Publication Analysis

Top Keywords

radiation exposure
12
imaging modalities
12
body mass
8
exposure imaging
8
chest pain
8
radiation effective
8
effective dose
8
imaging
6
radiation
5
bmi
5

Similar Publications