Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: We aimed to investigate risk factors for the recurrence of distal anterior cerebral artery (DACA) aneurysms after endovascular treatment (EVT).

Methods: The clinical and radiologic outcomes of DACA aneurysms treated with endovascular methods at a single tertiary hospital from September 2008 to December 2021 were retrospectively reviewed. We measured the angle between 2 distal branches of DACA aneurysms and categorized the angle as follows: 1) wide-angle (≥180°), and 2) narrow-angle type configuration (<180°). Univariate and multivariate analyses were performed to demonstrate the relationships between characteristics of DACA aneurysm and recurrence risk.

Results: In total, 132 DACA aneurysms were treated in our institution. Among these, 47 DACA aneurysms after EVT were included in this study. Forty patients underwent coil embolization without stent, 7 for stent-assisted coil embolization. At the last follow-up (mean 30.2 ± 24.2 months), overall recurrence rate was 23.4% (n = 11). Recurrence rate of the wide-angle type (9 of 23, 39.1%) was significantly greater than narrow-angle type (2 of 24, 8.3%) (P = 0.041; odds ratio 8.174, 95% confidence interval 1.094-61.066). Irregular shape of the DACA aneurysm also showed significantly greater recurrence rate (P = 0.011; odds ratio 10.663, 95% confidence interval 1.701-66.838) after endovascular treatment.

Conclusions: The wide-angle between 2 distal branches of DACA aneurysm and irregular shape might be independent risk factors for the recurrence after endovascular treatment for DACA aneurysms.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2024.03.161DOI Listing

Publication Analysis

Top Keywords

daca aneurysms
12
risk factors
8
factors recurrence
8
recurrence distal
8
distal anterior
8
anterior cerebral
8
cerebral artery
8
aneurysms endovascular
8
endovascular treatment
8
aneurysms
4

Similar Publications

Purpose: Treating small-caliber vessel aneurysms with flow diverters poses challenges due to narrow luminal diameters and tortuous vasculature, which complicate the navigation and deployment of conventional devices using standard microcatheters. The Silk Vista Baby (SVB, Balt, Montmorency, France) flow diverter was developed to treat intracranial aneurysms located in smaller vessels or more distal segments and is compatible with 0.017″ microcatheters.

View Article and Find Full Text PDF

A 60-year-old male patient presented with headache and vomiting following a fall. Computed Tomography (CT) brain imaging showed a subarachnoid hemorrhage due to aneurysm rupture in the anterior communicating artery (ACOM) and direct anterior cerebral artery (DACA). Right frontotemporal craniotomy and clipping of both ACOM and DACA aneurysms were performed.

View Article and Find Full Text PDF

The authors describe the case of multiple rare distal anterior cerebral artery (DACA) aneurysms related to a middle cerebral artery (MCA) aneurysm, an azygos, and an undescribed anterior cerebral artery (ACA) anatomical variation. A 61-year-old woman in a severe clinical state was diagnosed with subarachnoid hemorrhage (SAH) secondary to a ruptured anterior A3 DACA aneurysm. The patient also had unruptured kissing superior A3 DACA aneurysms, an atherosclerotic DACA aneurysm between the anterior and superior DACA aneurysms, and an unruptured MCA left aneurysm.

View Article and Find Full Text PDF

We report a case of distal anterior cerebral artery (DACA) aneurysm presenting with subdural hematoma (SDH) without subarachnoid hemorrhage (SAH). A patient in his fifties presented with headache. Fluid-attenuated inversion recovery magnetic resonance imaging revealed SDH in the interhemispheric fissure and left frontotemporal region.

View Article and Find Full Text PDF