Objective: This in-vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches.
Methods: Twenty-two abutment-level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS-A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS-B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross-arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05.
Results: In the spatial fit test, the precision of average 3D distances was 45 μm (±23 μm) with protocol IOS-A and 25 μm (±10 μm) for IOS-B (p < .001), and the trueness of average 3D distances was 44 μm (±24 μm) with protocol IOS-A and 24 μm (±7 μm) for IOS-B (p < .001). Cross-arch distance precision was 59 μm (±53 μm) for IOS-A and 41 μm (±43 μm) for IOS-B (p = .0035), and trueness was 64 μm (±47 μm) for IOS-A and 50 μm (±40 μm) for IOS-B (p = .0021). Virtual Sheffield precision was 286 μm (±198 μm) for IOS-A and 146 μm (±92 μm) for IOS-B (p < .001), and trueness was 228 μm (±171 μm) for IOS-A and 139 μm (±92 μm) for IOS-B (p < .001).
Conclusions: The IOS-B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete-arch intraoral scanning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.14259 | DOI Listing |
J Prosthodont
September 2025
Department of Graphic Design and Engineering Projects, Faculty of Engineering Gipuzkoa, University of the Basque Country UPV/EHU, San Sebastian, Spain.
Purpose: The aim of this in vitro study was to assess whether the accuracy (trueness and precision) of full-arch implant digital impressions can be improved by replacing standard digital impressions (StDIs) with segmented digital impressions (SgDIs), obtained by superimposing short-span digital impressions using a geometric pattern.
Materials And Methods: The study was conducted using a commercial edentulous maxillary model with four implants-positioned at the sites of the canines and second molars-and four commercial intraoral scan bodies (ISBs) screwed to them. Ten StDIs and SgDIs of the model were obtained, and their accuracy was evaluated and compared in terms of trueness and precision, based on measurements of three distances and three angles between the ISBs.
J Adv Prosthodont
August 2025
Department of Statistical Sciences, Alma Mater Studiorum, University of Bologna, Bologna, Italy.
Purpose: This study aims to compare the occlusal trueness and precision of teeth manufactured using two modern digital milling processes.
Materials And Methods: A total of 38 complete dentures (CDs) were fabricated and analyzed. CDs in Group 1 (monolithic) (n = 19) were produced using a monolithic bicolor resin disk, whereas in Group 2 (oversize) (n = 19) were fabricated using the oversize process, which involves two separate resin disks of different colors.
The present article describes a dental implant planning workflow to solve the CBCT artifact problem. The technique uses a radiopaque 3D-printed tray to take impressions and complete data alignment of the dental arches where implants are planned. From the impressions, 3D Boolean inversion is performed to obtain the surface mesh of teeth and virtually remove the undercut of dentition mesh before an implant surgical guide is designed.
View Article and Find Full Text PDFTalanta
August 2025
State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen, 361102, China; College of the Environment and Ecology, Xiamen University, Xiamen, 361102, China; National Observation and Research Station for the Taiwan Strait Marine Ecosystem, Xiamen University, Zhangzhou, 363000, Ch
Phosphate and nitrite, two essential nutrients in marine ecosystems, exhibit dynamic concentration distributions due to complex biogeochemical processes. Accurate quantification of these nutrients requires analytical methods with both high sensitivity and a broad dynamic range. Here, we present an automated syringe pump-based analyzer coupled with a long pathlength liquid waveguide capillary cell (LWCC), incorporating a robust automated dilution program, for simultaneous determination of phosphate and nitrite in seawater across nanomolar and micromolar concentrations.
View Article and Find Full Text PDFJ Dent
August 2025
Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey.
Objectives: To investigate the fabrication and fit accuracy of three-unit definitive resin fixed partial dentures (FPDs) manufactured with different vat polymerization technologies, and to compare them with those manufactured subtractively.
Methods: A total of 48 three-unit posterior fixed partial dentures (FPDs) were fabricated either additively from a resin intended for definitive use (VarseoSmile Triniq) with low force display (Form 4B, AM-LFD), digital light processing (Max UV, AM-DLP), and liquid crystal display (SOL, AM-LCD) technologies, or subtractively from high-impact polymer composite (breCAM.HIPC, SM) (n = 12).