A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimal Implant Sizing Using Machine Learning Is Associated With Increased Range of Motion After Cervical Disk Arthroplasty. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objectives: Cervical disk arthroplasty (CDA) offers the advantage of motion preservation in the treatment of focal cervical pathology. At present, implant sizing is performed using subjective tactile feedback and imaging of trial cages. This study aims to construct interpretable machine learning (IML) models to accurately predict postoperative range of motion (ROM) and identify the optimal implant sizes that maximize ROM in patients undergoing CDA.

Methods: Adult patients who underwent CDA for single-level disease from 2012 to 2020 were identified. Patient demographics, comorbidities, and outcomes were collected, including symptoms, examination findings, subsidence, and reoperation. Affected disk height, healthy rostral disk height, and implant height were collected at sequential time points. Linear regression and IML models, including bagged regression tree, bagged multivariate adaptive regression spline, and k-nearest neighbors, were used to predict ROM change. Model performance was assessed by calculating the root mean square error (RMSE) between predicted and actual changes in ROM in the validation cohort. Variable importance was assessed using RMSE loss. Area under the curve analyses were performed to identify the ideal implant size cutoffs in predicting improved ROM.

Results: Forty-seven patients were included. The average RMSE between predicted and actual ROM was 7.6° (range: 5.8-10.1) in the k-nearest neighbors model, 7.8° (range: 6.5-10.0) in the bagged regression tree model, 7.8° (range: 6.2-10.0) in the bagged multivariate adaptive regression spline model, and 15.8° (range: 14.3-17.5°) in a linear regression model. In the highest-performing IML model, graft size was the most important predictor with RMSE loss of 6.2, followed by age (RMSE loss = 5.9) and preoperative caudal disk height (RMSE loss = 5.8). Implant size at 110% of the normal adjacent disk height was the optimal cutoff associated with improved ROM.

Conclusion: IML models can reliably predict change in ROM after CDA within an average of 7.6 degrees of error. Implants sized comparably with the healthy adjacent disk may maximize ROM.

Download full-text PDF

Source
http://dx.doi.org/10.1227/neu.0000000000002924DOI Listing

Publication Analysis

Top Keywords

disk height
16
rmse loss
16
iml models
12
optimal implant
8
implant sizing
8
machine learning
8
range motion
8
cervical disk
8
disk arthroplasty
8
maximize rom
8

Similar Publications