Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Cardiac implantable electronic device (CIED) infection is a costly and highly morbid complication. Perioperative interventions, including the use of antibiotic pouches and intensified perioperative antibiotic regimens, have demonstrated marginal efficacy at reducing CIED infection. Additional research is needed to identify additional interventions to reduce infection risk.

Objective: We sought to evaluate whether adherent skin barrier drape use is associated with a reduction in CIED infection.

Methods: A prospective registry of all CIED implantation procedures was established at our institution in January 2007. The registry was established in collaboration with our hospital infection prevention team with a specific focus on prospectively identifying all potential CIED infections. All potential CIED infections were independently adjudicated by 2 physicians blinded to the use of an adherent skin barrier drape.

Results: Over a 13-year period, 14,225 procedures were completed (mean age 72 ± 14 years; female 4,918 (35%); new implants 10,005 (70%); pulse generator changes 2585 (18%); upgrades 1635 (11%). Of those, 2469 procedures (17.4%) were performed using an adherent skin barrier drape. There were 103 adjudicated device infections (0.73%). The infection rate in patients in the barrier use groups was 8 of 2469 (0.32%) as compared with 95 of 11,756 (0.8%) in the nonuse group ( = .0084). In multivariable analysis, the use of an adherent skin barrier drape was independently associated with a reduction in infection (odds ratio 0.32; 95% confidence interval 0.154-0.665; = .002).

Conclusion: The use of an adherent skin barrier drape at the time of cardiac device surgery is associated with a lower risk of subsequent infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10964373PMC
http://dx.doi.org/10.1016/j.hroo.2023.12.002DOI Listing

Publication Analysis

Top Keywords

adherent skin
24
skin barrier
24
barrier drape
20
drape associated
8
cardiac implantable
8
infection
8
14225 procedures
8
cied infection
8
associated reduction
8
potential cied
8

Similar Publications

Delayed autografting in the face and hands: The role of allografts in burn wound bed preparation.

JPRAS Open

September 2025

Department of Plastic, Reconstructive, & Aesthetic Surgery, Singapore General Hospital, Outram Road, Singapore 169608, Singapore.

Introduction: Burn injuries affecting specialised areas such as the face and hands require durable skin coverage and complete graft "take" to prevent scarring and functional impairment. Failure to achieve these outcomes can lead to long-term complications. This presentation aims to describe an approach of delayed autografting in these regions, following a "trial of allograft" to optimise wound bed preparation.

View Article and Find Full Text PDF

Background: Filarial lymphedema, caused by lymphatic filariasis, is characterized by chronic swelling and recurrent skin infections. Acute adenolymphangitis (ADL) episodes significantly exacerbate morbidity. Diabetes mellitus (DM) increases susceptibility to infections; however, the relationship between diabetes and ADL frequency and severity in filarial lymphedema patients remains unclear.

View Article and Find Full Text PDF

Methods to Validate Digital Health Technologies for Dermatology.

J Invest Dermatol

September 2025

Department of Dermatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA; Sibel Health, Chicago, Illinois, USA; Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois, USA. Electronic address:

The integration of wearable medical devices and digital health technologies (DHTs) in health care has grown significantly during the past 2 decades, particularly in dermatology, in which objective measurement of symptoms such as itch remains challenging. This review examines the evolution of DHTs in dermatology, focusing on the validation frameworks necessary for their implementation in clinical trials and research. We discuss the key stages of validation: hardware validation to ensure device reliability, analytical validation to transform raw sensor data into meaningful metrics, and clinical validation to demonstrate utility in specific patient populations.

View Article and Find Full Text PDF

Nosocomial meningitis following spinal anesthesia is a rare but potentially life-threatening complication that breaches the central nervous system's natural defense barriers. This report presents a case of meningitis post spinal anesthesia, emphasizing the diagnostic, management, and preventive strategies for iatrogenic bacterial meningitis. A 53-year-old patient with sickle cell disease developed febrile confusion 10 days after spinal anesthesia for hemorrhoidal surgery, presenting with meningeal signs and positive infectious markers.

View Article and Find Full Text PDF

Bioactive hydroxyapatite-sodium silicate waterglass reinforced with nanocollagen from Chitala ornata fish skin for bone engineering.

Int J Biol Macromol

September 2025

The Materials Engineering Department, Faculty of Engineering, Kasetsart University, Phaholyothin Rd., Bangkok 10900, Thailand. Electronic address:

A prototype bioactive calcium phosphate model-specifically hydroxyapatite (HA) derived from eggshells-was developed using a sodium silicate (NaSiO) solution as an inorganic binder, precursor, and reinforcing agent, in combination with collagen nanofibers for bone engineering applications. The sodium silicate solution, functioning as a waterglass adhesive, introduced cohesive forces within the hydroxyapatite matrix, thereby enhancing its physical, chemical, and mechanical properties. Eggshell-derived bioactive hydroxyapatite offers several advantages, including non-toxicity, biocompatibility, collagen adhesion, and the ability to mimic bone structure, making it suitable for tissue engineering.

View Article and Find Full Text PDF