Article Abstract

Liver stiffness measurement (LSM) by Fibroscan is the most used non-invasive method to assess liver fibrosis. Recently, point-shear wave elastography (pSWE) has been introduced as a simple alternative non-invasive test. Therefore, we aimed to compare the results of these two techniques. One hundred and eighty-four consecutive patients attending our outpatient ultrasound clinic were recruited. LSM was performed by both Fibroscan and pSWE. Statistical analysis was conducted by Spearman's test for correlation and linear regression. Bland-Altman graphs and ROC curves were drawn with area under the curve (AUC). Overall, the correlation of LS between Fibroscan and pSWE was substantial (r = 0.68, < 0.001). Linear regression showed a coefficient b= 0.94 ± 0.02. The Bland-Altman plot found a bias of -0.10, with only 11 values exceeding the 95% confidence interval. When only considering patients with a LSM of > 10 kPa ( = 31), we found an excellent r = 0.79 (0.60-0.90, < 0.001). A cutoff of 12.15 kPa for pSWE had sensitivity = 74.2% and specificity = 99.3% to detect relevant fibrosis, with an AUC = 0.98. The highest correlation was observed for hepatitis C (r = 0.91) and alcoholic liver disease (ALD)(r = 0.99). In conclusion, pSWE shows LSM estimation in agreement with Fibroscan in most cases, and the best concordance was observed for hepatitis C and ALD, and for higher ranges of LS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10968920PMC
http://dx.doi.org/10.3390/diagnostics14060604DOI Listing

Publication Analysis

Top Keywords

wave elastography
8
liver stiffness
8
fibroscan pswe
8
linear regression
8
observed hepatitis
8
pswe
5
comparison transient
4
transient elastography
4
elastography point
4
point shear
4

Similar Publications

The objective of this study was to assess the link between postpartum blood loss and placental elastography in multiparous pregnancies.In this prospective study, multiparous women who delivered at term between 2020 and 2024 were included. During the obstetric ultrasonography procedure, placental elastography was evaluated through the utilization of the shear wave elastography (SWE) technique.

View Article and Find Full Text PDF

Alterations in skeletal muscle morphology and composition are critical factors in cerebral palsy (CP), including changes in passive stiffness and in belly and fascicle lengths. In this study, we quantified the relative contributions of muscle and tendon to passive stiffness across the ankle range of motion in individuals with CP and typically developing (TD) peers. We also investigated morphological factors underlying increased muscle stiffness.

View Article and Find Full Text PDF

Background: Hepatic sinusoidal obstruction syndrome (SOS), or veno-occlusive disease (VOD), is a severe complication following hematopoietic stem cell transplantation (HSCT), often leading to liver dysfunction and poor outcomes if not detected early. Traditional diagnostic methods, including ultrasound and liver biopsy, have limitations in sensitivity and feasibility. Non-invasive elastography techniques, such as transient elastography (TE) and shear-wave elastography (SWE), offer a promising alternative by quantitatively assessing liver stiffness.

View Article and Find Full Text PDF

Multiparametric Ultrasound for Preoperative Assessment of Parotid Tumors: A Novel Diagnostic Pathway.

Head Neck

September 2025

Department of Radiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Zu Berlin, and Berlin Institute of Health, Berlin, Germany.

Background: Accurate preoperative differentiation of parotid gland tumors (PGTs) is essential for facial nerve preservation. This study evaluates a novel, real-time multiparametric ultrasound (mpUS) approach combining B-mode, shear wave elastography (SWE), and contrast-enhanced ultrasound (CEUS), based on qualitative image interpretation.

Methods: Eighty-nine patients with 91 PGTs underwent mpUS prior to surgery or ultrasound-guided biopsy.

View Article and Find Full Text PDF

Objective: The most common chronic complication of vesicoureteral reflux (VUR) is the presence of renal scarring and dimercapto succinic acid (DMSA) renal scan is utilized for its detection. In this study, we have aimed to assess whether shear wave speed (SWS) differs between normal and refluxing kidneys.