Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Introduction: Microcirculation of optic nerve head (ONH) in open-angle glaucoma (OAG) patients with unilateral visual field (VF) loss has yet to be fully investigated, especially the perimetrically unaffected fellow eyes.
Methods: Thirty-eight OAG patients with VF defect in one eye and normal VF in the other eye, and thirty-one healthy participants were analyzed. All participants underwent laser speckle flowgraphy (LSFG), spectral-domain optical coherence tomography (SD-OCT) imaging, and VF test for further analyses. LSFG measurements included mean blur rate in all area of ONH (MA), big vessel area of ONH (MV), and tissue area of ONH (MT). SD-OCT parameters included circumpapillary retinal nerve fiber layer (cpRNFL) thickness and macula thicknesses. The difference of LSFG and SD-OCT indices between glaucoma patients and healthy controls were compared. The diagnostic accuracy was analyzed with the areas under the receiver operating characteristic curves (AROCs).
Results: Global cpRNFL thickness and macular thickness in unaffected eyes of OAG patients were higher than their fellow eyes and lower than healthy eyes. MA and MV in healthy eyes and unaffected eyes were significantly higher than in affected eyes. MT in unaffected eyes of OAG patients was higher than in their fellow affected eyes but lower than in healthy eyes. The AROCs were highest for cpRNFL (0.925), followed by macular thickness (0.838), and MT (0.834).
Conclusions: ONH microcirculation in perimetrically unaffected fellow eyes was decreased in OAG patients with unilateral VF loss. LSFG can detect changes of ONH in high-risk eyes before detectable VF damage, which may reflect the vascular pathophysiology for glaucoma.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000538407 | DOI Listing |