Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]).

Aims: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV.

Methods: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching.

Results: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients.

Conclusions: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10941672PMC
http://dx.doi.org/10.4244/EIJ-D-23-00779DOI Listing

Publication Analysis

Top Keywords

device success
24
technical success
12
success
9
self-expanding transcatheter
8
transcatheter heart
8
degenerated surgical
8
multicentre registry
8
rates severe
8
success acurate
8
success higher
8

Similar Publications

BackgroundA stable guiding system is essential for successful carotid artery stenting (CAS), particularly when navigating tortuous aortic or supra-aortic anatomy. However, data on the mechanical behavior of stent delivery systems remain scarce.ObjectiveTo assess and compare the bending stiffness and trackability of five commercially available carotid stent delivery systems using bench-top experiments.

View Article and Find Full Text PDF

The role of intravenous thrombolysis (IVT) in patients with tandem lesions (TL) undergoing endovascular thrombectomy (EVT) for acute ischemic stroke (AIS) remains a subject of ongoing debate. The substantial clot burden and the potential need for periprocedural antiplatelet therapy during emergent carotid stenting (CAS) add to the complexity of treatment decisions. This study aims to systematically review and meta-analyze the literature to evaluate the comparative safety and efficacy of IVT plus EVT versus EVT alone in AIS patients with TL.

View Article and Find Full Text PDF

Background: Certain 3D interrelationships between adjacent implants can potentially predispose to prosthetic and biological complications.

Materials And Methods: Patient records with adjacent dental implants were assessed to evaluate the effects of vertical, horizontal and angulation interrelationships between splinted compared to non-splinted implant restorations on the occurrence of biological and prosthetic complications. Data on patient- and implant-related variables were collected at baseline (T1) during prosthesis placement and at the last follow-up appointment (T2).

View Article and Find Full Text PDF

Functional reconstruction of large mandibular defects, especially in young patients, presents a significant clinical challenge. The ideal approach should not only restore skeletal contour but also address nerve deficits and facilitate final occlusal rehabilitation, all while minimizing morbidity. This report describes a comprehensive, multi-staged strategy for such a case.

View Article and Find Full Text PDF

Aim: Positive expiratory pressure devices are frequently used for airway clearance in children with cystic fibrosis and tracheobronchomalacia. This study aimed to establish if electrical impedance tomography is a feasible measure to titrate pressures in non-sedated children.

Method: Ten children with cystic fibrosis and tracheobronchomalacia performed airway clearance using positive pressure devices whilst monitored with electrical impedance tomography.

View Article and Find Full Text PDF