98%
921
2 minutes
20
Objective: The gold standard of oral cancer (OC) treatment is diagnostic confirmation by biopsy followed by surgical treatment. However, studies have shown that dentists have difficulty performing biopsies, dental students lack knowledge about OC, and surgeons do not always maintain a safe margin during tumor resection. To address this, biopsies and resections could be trained under realistic conditions outside the patient. The aim of this study was to develop and to validate a porcine pseudotumor model of the tongue.
Methods: An interdisciplinary team reflecting various specialties involved in the oncological treatment of head and neck oncology developed a porcine pseudotumor model of the tongue in which biopsies and resections can be practiced. The refined model was validated in a final trial of 10 participants who each resected four pseudotumors on a tongue, resulting in a total of 40 resected pseudotumors. The participants (7 residents and 3 specialists) had an experience in OC treatment ranging from 0.5 to 27 years. Resection margins (minimum and maximum) were assessed macroscopically and compared beside self-assessed margins and resection time between residents and specialists. Furthermore, the model was evaluated using Likert-type questions on haptic and radiological fidelity, its usefulness as a training model, as well as its imageability using CT and ultrasound.
Results: The model haptically resembles OC (3.0 ± 0.5; 4-point Likert scale), can be visualized with medical imaging and macroscopically evaluated immediately after resection providing feedback. Although, participants (3.2 ± 0.4) tended to agree that they had resected the pseudotumor with an ideal safety margin (10 mm), the mean minimum resection margin was insufficient at 4.2 ± 1.2 mm (mean ± SD), comparable to reported margins in literature. Simultaneously, a maximum resection margin of 18.4 ± 6.1 mm was measured, indicating partial over-resection. Although specialists were faster at resection (p < 0.001), this had no effect on margins (p = 0.114). Overall, the model was well received by the participants, and they could see it being implemented in training (3.7 ± 0.5).
Conclusion: The model, which is cost-effective, cryopreservable, and provides a risk-free training environment, is ideal for training in OC biopsy and resection and could be incorporated into dental, medical, or oncologic surgery curricula. Future studies should evaluate the long-term training effects using this model and its potential impact on improving patient outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10949621 | PMC |
http://dx.doi.org/10.1186/s12909-024-05224-5 | DOI Listing |
Rep U S
October 2024
Jiawei Ge, Justin D. Opfermann, and Axel Krieger are with the Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21211, USA.
In soft tissue surgeries, such as tumor resections, achieving precision is of utmost importance. Surgeons conventionally achieve this precision through intraoperative adjustments to the cutting plan, responding to deformations from tool-tissue interactions. This study examines the integration of physics-based tissue cutting simulations into autonomous robotic surgery to preoperatively predict and compensate for such deformations, aiming to improve surgical precision and reduce the necessity for dynamic adjustments during autonomous surgeries.
View Article and Find Full Text PDFInt J Hyperthermia
December 2025
Department of Radiology, University of Wisconsin, Madison, WI, USA.
Purpose: The application of histotripsy, an emerging noninvasive, non-ionizing, and non-thermal tumor treatment, is currently limited by the inherent limitations of diagnostic ultrasound as the sole targeting modality. This study evaluates the feasibility and accuracy of cone beam computed tomography (CBCT) guidance for histotripsy treatments in an porcine model.
Materials And Methods: Histotripsy treatments were performed in the liver of seven healthy swine under the guidance of a C-arm CBCT system that was calibrated to the robotic arm of the histotripsy system.
Cureus
April 2024
Department of Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND.
One of the most dangerous parasite infections, cysticercosis, is found practically everywhere in the world. Cysticercus cellulosae is the larval stage of the swine tapeworm Taenia solium, which causes cysticercosis. Orbital or ocular cysticercosis (OOC) is an avoidable cause of blindness.
View Article and Find Full Text PDFBMC Med Educ
March 2024
Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
Objective: The gold standard of oral cancer (OC) treatment is diagnostic confirmation by biopsy followed by surgical treatment. However, studies have shown that dentists have difficulty performing biopsies, dental students lack knowledge about OC, and surgeons do not always maintain a safe margin during tumor resection. To address this, biopsies and resections could be trained under realistic conditions outside the patient.
View Article and Find Full Text PDFIEEE Robot Autom Lett
February 2024
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21211 USA.
Head and neck cancers are the seventh most common cancers worldwide, with squamous cell carcinoma being the most prevalent histologic subtype. Surgical resection is a primary treatment modality for many patients with head and neck squamous cell carcinoma, and accurately identifying tumor boundaries and ensuring sufficient resection margins are critical for optimizing oncologic outcomes. This study presents an innovative autonomous system for tumor resection (ASTR) and conducts a feasibility study by performing supervised autonomous midline partial glossectomy for pseudotumor with millimeter accuracy.
View Article and Find Full Text PDF